background image

Z

Z5384/Z5551

Mounting instructions 1.4 en

Содержание Z5384

Страница 1: ...Z Z5384 Z5551 Mounting instructions 1 4 en ...

Страница 2: ... all rights reserved Keep this document with the product or in a safe place so that it is available for future reference When reselling this product hand over this document to the new owner d b audiotechnik GmbH Co KG Eugen Adolff Str 134 D 71522 Backnang Germany T 49 7191 9669 0 F 49 7191 95 00 00 docadmin dbaudio com www dbaudio com ...

Страница 3: ...384 Assembly 6 2 4 Z5384 Adjustments 6 3 Z5551 VP Flying adapter link 7 3 1 Z5551 Scope of supply 7 3 2 Z5551 Intended use 7 3 3 Z5551 Assembly 7 4 Maintenance and care 9 4 1 Inspections 9 5 Manufacturer s declaration 10 5 1 EU conformity CE symbol 10 5 2 Disposal 10 Contents d b Z5384 Z5551 Mounting instructions 1 4 en 3 ...

Страница 4: ...the intended use Always carry out a visual and functional inspection of the items before use In case there is any doubt as to the proper functioning and safety of the items these must be withdrawn from use immediately Load safety information The maximum permitted working load of the Flying adapter corresponds to a weight of a maximum of two V Point or Vi Point cabinets flown one below the other No...

Страница 5: ...tated in the respective manuals mounting instructions Together with the supplied E6507 1t Shackle to suspend the cabinets using a steel wire rope or chain Together with the d b Z5015 TV spigot and Z5012 Pipe clamp to attach a single cabinet to overhead bars or truss with a tube diameter of up to 70 mm 2 75 Alternatively the d b Z5147 Rota clamp can be used Together with the optional d b Z5551 VP F...

Страница 6: ...s as listed in the table below The vertical angle is related to the center of gravity of the cabinet Hole grid 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Angle VP ViP 17 13 8 5 4 5 0 4 5 8 5 13 17 21 25 29 33 36 Angle 24S 24S D 18 14 5 10 5 6 5 2 5 1 5 5 5 9 5 13 17 21 25 28 5 32 Positive value Cabinet points upwards Negative value Cabinet points downwards Horizontal aiming The horizontal aiming is adjusted...

Страница 7: ... of the cabinets Splay angle settings Starting from hole eight 8 towards the back the Flying adapter together with the link allows the setting of vertical splay angles ranging from 5 to 30 in increments of 5 Hole 8 9 9 10 10 11 11 12 12 13 13 14 Splay 5 10 15 20 25 30 3 3 Z5551 Assembly Preparing the cabinets For this application two additional Flying adapters are required The attachment of the Fl...

Страница 8: ...econd flying adapter hole 8 is in line with the link 5 Insert one locking pin 6 Slightly lift the entire assembly 7 Raise the bottom cabinet until the second hole hole 9 is in line with the link and insert the second Locking pin 8 Recheck your work before lifting the assembly to its operating position Ensure all four Locking pins are fully inserted and properly locked Joining the cabinets Shown Ho...

Страница 9: ... of the components carry out regular visual and functional inspections of the components If the components fail to operate correctly and or safely the adapter must be withdrawn from use immediately Flying adapter and link In particular pay attention to obvious damage deformation cracks and corrosion Locking pins Visual inspection for deformation cracks and corrosion of the component Inspection for...

Страница 10: ... that said products are in conformity with the provisions of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 5 2 Disposal When out of use the rigging components must be disposed of in accordance with the national environmental regulations Ensure that dam...

Страница 11: ...D2822 EN 01 04 2020 d b audiotechnik GmbH Co KG www dbaudio com ...