background image

Содержание Y Series

Страница 1: ...Y Y8 Y12 Manual 1 2 en ...

Страница 2: ...ly check the d b website for the latest version of this document When reselling this product hand over this document to the new owner If you supply d b products please draw the attention of your customers to this document Enclose the relevant documents with the systems If you require additional documents for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Straße 134 D 7...

Страница 3: ... 1 Product description 5 2 2 Connections 6 2 3 Operation 6 2 3 1 Controller settings 7 2 4 Dispersion characteristics 8 2 5 Technical specifications 9 3 Manufacturer s declarations 10 3 1 EU conformity of loudspeakers CE symbol 10 3 1 1 WEEE Declaration Disposal 10 Contents d b Y8 Y12 Manual 1 2 en 3 ...

Страница 4: ...ries as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories for vis...

Страница 5: ...xtends from 54 Hz to above 19 kHz The cabinets are constructed from marine plywood and have an impact and weather protected PCP Polyurea Cabinet Protection finish The fronts of the cabinets are protected by a rigid metal grill backed by an acoustically transparent foam Each side panel incorporates a handle while two additional recessed grips are provided at the rear Y Series rigging components and...

Страница 6: ...atch is therefore independent of the connector type used 2 3 Operation NOTICE Only operate d b loudspeakers with a correctly configured d b amplifier otherwise there is a risk of damaging the loudspeaker components Applicable d b amplifiers D80 D20 D12 D6 10D 30D Application Setup Cabinets per channel Y8 Y8 Arc Y8 Line 2 Y12 Y12 Arc Y12 Line 2 The applicable d b amplifiers provide two setups Arc o...

Страница 7: ... system is used in full range mode without subwoofers Note Make sure that all cabinets within the line array are operated with the same CPL setting HFC function Selecting the HFC High Frequency Compensation function compensates for the loss of high frequency energy due to air absorption when loudspeakers are used to cover far field listening positions The HFC function has two settings HFC1 and HFC...

Страница 8: ...r frequency plotted using lines of equal sound pressure isobars at 6 dB and 12 dB The nominal dispersion is maintained above 600 Hz while a useful horizontal dispersion control is achieved down to 500 Hz Isobar diagram Y12 horizontal Isobar diagram Y8 horizontal d b Y8 Y12 Manual 1 2 en 8 ...

Страница 9: ... ohms Power handling capacity RMS peak 10 ms 400 1600 W Nominal dispersion angle horizontal Y8 80 Nominal dispersion angle horizontal Y12 120 Splay angle setting 0 14 1 increment Components 2 x 8 driver 1 x 1 4 exit compression driver Passive crossover network Connections 2 x NLT4 F M optional 2 x NL4 M or EP5 Pin assignment NLT4 F M and NL4 M 1 1 EP5 1 2 Weight 20 kg 44 lb Y8 Y12 cabinet dimensio...

Страница 10: ...ons of the respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 1 1 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to...

Страница 11: ......

Страница 12: ...D2712 EN 01 10 2016 d b audiotechnik GmbH www dbaudio com ...

Отзывы: