background image

 

AP setup
In connection with d&b ArrayProcessing (AP), the AP setup

contains the AP data that is generated by the d&b ArrayCalc

simulation software and transferred to the applicable amplifiers via

the d&b Remote network (OCA/AES70) using R1.
As soon as the data has been sent to the amplifiers, the AP setup is

automatically activated.

2.3.1  Controller settings

For acoustic adjustment the INFRA mode can be selected.

INFRA mode
With the INFRA mode selected, the frequency response of the

system extends from 35 Hz to 85 Hz.
The XSLi-SUB/XSLi-GSUB can now be used to supplement

applicable d&b loudspeaker systems operated in full range mode.

2.4  Technical specifications

System data

Frequency response (–5 dB standard)

37 Hz - 110 Hz

Frequency response (–5 dB INFRA)

35 Hz - 85 Hz

Max. sound pressure (1 m, free field) with 40D

137 dB

(SPLmax: Broadband signal IEC 60268)

Loudspeaker data

Nominal impedance front/rear

8/16 ohms

Power handling capacity front (RMS/peak 10 ms)

700/1500 W

Power handling capacity rear (RMS/peak 10 ms)

400/800 W

Components

1 x 18" driver front/1 x 12" driver rear

Connections

1 x NLT4 F/M

Pin assignment

1+: Front+/1–: Front– /2+: Rear+/2–: Rear–

Phoenix option

Phoenix socket (Type: DFK PC 4/4 GF)

Phoenix plug (Type: SPC 5/4)

Optional front splay (XSLi-SUB)

0° or 2.5°

Weight XSLi-SUB

66 kg (146 lb)

Weight XSLi-GSUB

62 kg (136 lb)

XSLi-SUB frequency response, standard and INFRA mode

 

d&b XSLi-SUB/XSLi-GSUB Manual 1.2 en

8

Содержание XSLi-SUB

Страница 1: ...SL XSLi SUB XSLi GSUB Manual 1 2 en...

Страница 2: ...rights reserved Keep this document with the product or in a safe place so that it is available for future reference When reselling this product hand over this document to the new owner d b audiotechni...

Страница 3: ...peaker 6 2 1 Intended use 6 2 2 Connections 7 2 3 Operation 7 2 3 1 Controller settings 8 2 4 Technical specifications 8 3 Manufacturer s declarations 10 3 1 Conformity of loudspeakers 10 3 2 WEEE Dec...

Страница 4: ...imum load capacity of the accessories as detailed in our specific Mounting instructions or in our Rigging manuals Ensure that all additional hardware fixings and fasteners used for deployment are of a...

Страница 5: ...cs In addition ArrayCalc will provide you with typical array configurations within the permitted load limits and will help you get familiar with the mechanical load conditions and limitations d b TI 3...

Страница 6: ...independent bass reflex chambers Through its cardioid dispersion pattern this setup avoids unwanted energy behind the system and greatly reduces the reverberant field at low frequencies providing high...

Страница 7: ...Pins 1 2 feeding the forward LF driver Pins 3 4 feeding the rear LF driver A corresponding Phoenix plug type SPC 5 4 is enclosed with the cabinet d b LoadMatch With the d b four channel amplifier plat...

Страница 8: ...tems operated in full range mode 2 4 Technical specifications System data Frequency response 5 dB standard 37 Hz 110 Hz Frequency response 5 dB INFRA 35 Hz 85 Hz Max sound pressure 1 m free field with...

Страница 9: ...XSLi SUB cabinet dimensions in mm inch The same dimensions apply to the XSLi GSUB d b XSLi SUB XSLi GSUB Manual 1 2 en 9...

Страница 10: ...uding all applicable amendments Detailed and applicable declarations are available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 2 WEEE Declaration Dis...

Страница 11: ...D2755 EN 01 09 2022 d b audiotechnik GmbH Co KG www dbaudio com...

Отзывы: