background image

20  d&b Q-Series 

The D6 and D12 amplifiers

The D6 and D12 are dual channel amplifiers developed and 
manufactured by d&b utilizing Digital Signal Processing (DSP) to 
incorporate loudspeaker specific configuration information and
functions. These are designed for use with d&b loudspeakers, 
have both digital and analog signal inputs as well as link outputs, 
remote control and monitoring capabilities and switch mode power 
supplies. The level control incorporates a digital rotary encoder 
enabling selection of all operating modes in conjunction with a 
Liquid Crystal Display (LCD).
Loudspeaker specific configurations for current d&b loudspeakers 
and a linear mode are contained within them, the exception 
being that the D6 does not include 2-Way Active, V-Series and 
B2-SUB configurations.
The digital elements of the D6 and D12 are specified and 
constructed to achieve the best possible audio performance while 
maintaining a very low latency of 0.3 msec. The Digital Signal 
Processing is used to provide the loudspeaker specific configurations, 
sophisticated protection circuits modelling thermal and mechanical 
driver behaviour, and switch functions.
User definable equalization and delay functions are incorporated 
in each channel of the amplifiers and can be used for applications 
such as front fills or under balcony delays without the need for 
external processors. The signal delay capability allows delay 
settings of up to 340 msec. (= 100 m/328 ft) to be applied 
independently to each channel as can the 4-band parametric 
equalizer, providing optional Boost/Cut or Notch filtering. A 
signal generator offering pink noise or sine wave program is also 
incorporated for test and alignment purposes. Every unit can be 
given a unique Device Name to simplify identification and a 
password protected LOCK function is also incorporated to prevent 
unauthorized changes. 
The D6 and D12 amplifiers also detect incoming Pilot signals at 
its input (Input monitoring) and can use Load monitoring and 
System check functions to determine the status of the loudspeaker 
impedance. d&b System check is designed to verify that the 
system performs within a predefined condition and can be used 
to report the system condition after a show.

d&b Load monitoring, on the other hand, enables automatic and
continuous impedance monitoring and along with Input monitoring 
is designed for incorporation within applications specified to the
requirements stated in the International Standard IEC 60849 
‘Sound Systems for Emergency Purposes’. Both can determine the 
status of an LF or HF driver in systems with multiple elements, 
even if these are crossed over passively.
The D6 utilizes a switch mode power supply with PFC suitable for 
mains supply voltages 100 V/115 V/200 V/230 V, 50 - 60 Hz 
whilst the D12 utilizes an autosensing switch mode power supply 
for mains voltages 115/230 V, 50 - 60 Hz (optional 100/200 V). 
Both power supplies have overvoltage protection and each 
amplifier has a temperature and signal controlled fan to cool the 
internal assemblies.
The 2 RU lightweight D6 is specifically designed to deliver medium
power into low impedance loads between 4 and 16 ohms. The 
3 RU D12 is specifically designed to produce high power into 
low impedance loads, typically those between 4 and 16 ohms. 
Due to differences in impedance response against frequency, the 
maximum number of cabinets driven by each D12 channel varies 
depending on the loudspeaker type.
Apart from selectable output configurations for dual channel, Mix 
TOP/SUB and 2-Way Active mode, the D12 also provides d&b 
SenseDrive for use with the LF drivers in d&b active loudspeakers 
and subwoofers.
Both amplifiers house an I/O panel containing: analog signal 
inputs with link outputs for each channel, an AES/EBU digital 
input with a link output and NL4 loudspeaker outputs. The D12 
I/O panel additionally offers the options of EP5 or NL8 
loudspeaker outputs. The two RJ 45 REMOTE sockets at the rear 
of the D6 and the D12 amplifiers integrate them into the d&b 
Remote network via CAN-Bus, enabling remote control and/or 
monitoring.
A USB-B (D6) or a SUB-D9 (D12) SERVICE interface is provided 
to enable future firmware updates containing new loudspeaker 
configurations or additional functions to be loaded to the units.

D6

VOLTAGE SEE LABEL
~ 50/60 Hz, 1000 W

MAINS SUPPLY

DIGITAL    AES/EBU

ANALOG

OUT

B

OUT

A

CH A

CH B

SERVICE

REMOTE

D6 rear view

D12 rear view

Содержание D12

Страница 1: ...The Q Series ...

Страница 2: ...15 The Qi rigging system 16 The Qi7 Qi10 rigging examples 16 The Qi7 Qi10 mounting and rigging accessories and examples 17 The d b ArrayCalc calculator 18 The D6 and D12 amplifiers 20 The D6 and D12 amplifier data 21 The operation with D6 and D12 amplifiers 22 The Q Series frequency responses 23 The Q Series configuration examples 24 The Qi loudspeakers Weather Resistant and Special Colour options...

Страница 3: ...ld integrated sound reinforcement systems that were more than the sum of their parts Each element is tightly specified precisely aligned and carefully integrated to achieve maximum possible performance along with neutral sound characteristics At the same time d b offers integrated training technical information expert service and support as well as a knowledgeable distribution network so that the ...

Страница 4: ... frequency drivers mechanically time aligns these with the 1 3 exit HF driver The Q1 Qi1 HF drivers are fitted with a toroidal wave shaping device which have a 75 h and 75 x 15 h x v dispersion pattern respectively the resulting curved coherent wave front allows vertical arrays of multiple cabinets to be constructed The Q7 Qi7 and Q10 Qi10 loudspeakers also use a 1 3 HF driver fitted to rotatable ...

Страница 5: ...d b Q Series 5 D12 amplifier D6 amplifier The Q Series Q subwoofer Q7 Q10 loudspeaker Q1 loudspeaker Qi QiCSA subwoofer Qi7 Qi10 loudspeaker Qi1 loudspeaker ...

Страница 6: ...ve an impact resistant paint finish The front of the loudspeaker cabinets are covered with a replaceable acoustically transparent foam and protected by a rigid metal grill Four M10 threaded inserts on each side panel of the Qi1 cabinet enclosure are provided for attaching installation hardware whilst the Q1 cabinet incorporates a pair of handles and has integrated line array rigging hardware Syste...

Страница 7: ...d protected by a rigid metal grill Four M10 threaded inserts on each side panel of the Qi7 cabinet enclosure are provided for attaching installation hardware whilst the Q7 cabinet incorporates a pair of handles and has integrated line array rigging hardware System data Frequency response 5 dB standard 60 Hz 17 kHz Frequency response 5 dB CUT mode 100 Hz 17 kHz Max sound pressure 1 m free field 1 w...

Страница 8: ...er cabinets are covered with a replaceable acoustically transparent foam and protected by a rigid metal grill Four M10 threaded inserts on each side panel of the Qi10 cabinet enclosure are provided for attaching installation hardware whilst the Q10 cabinet incorporates a pair of handles and has integrated rigging hardware System data Frequency response 5 dB standard 60 Hz 17 kHz Frequency response...

Страница 9: ...lly transparent foam and protected by a rigid metal grill The QiCSA SUB cabinet has foams fitted to both the front and rear sides of the cabinet the grill facing backwards is fitted with a single NL4 connector see page15 Four M10 threaded inserts on each side panel of the Qi and QiCSA SUB enclosure are provided for attaching installation hardware whilst the Q SUB cabinet incorporates a pair of han...

Страница 10: ...ree Q1 loudspeakers maximum Z5048 Flying pin 10 mm Z5151 Q Splay link Z5154 Q Rigging set Z5160 Q Load adapter WLL 480 kg 1058 lb or twenty Q1 loudspeakers aiming of a column by 1 1 1 2 or 1 4 detents Z5152 Q Front link Z5155 Q Hoist connector chain WLL 480 kg 1058 lb or twenty Q1 loudspeakers E6507 1t Shackle Z5153 Locking pins 8 mm Z5159 Q Flying frame WLL 480 kg 1058 lb or twenty Q1 loudspeaker...

Страница 11: ...enty cabinets with a fully user and venue defined vertical profile For further information please refer to the TI 385 d b Line array design and Q Series Rigging manual which are available for download at www dbaudio com Q1 array with Z5156 Q Flying adapter Z5154 Q Rigging set Z5147 Rota clamp Q1 line array with Z5159 Q Flying frame Z5154 Q Rigging set Z5155 Q Hoist connector chain E6507 1t Shackle...

Страница 12: ...Z5048 Flying pin 10 mm Z5150 Q Swivel bracket Z5020 Flying adapter 02 Z5161 Q Flying bracket Z5025 Flying adapter 03 Z5012 Pipe clamp for TV spigot WLL 100 kg 220 lb for a tube diameter up to 70 mm 2 75 Z5015 TV spigot 02 Z5147 Rota clamp WLL 500 kg 1100 lb for a tube diameter up to 51 mm 2 Q9032 Safety eyebolt M10 E6507 1t Shackle Z5010 TV spigot with fixing plate Z5024 Loudspeaker stand adapter ...

Страница 13: ...d winder M20 Q7 Q10 with Z5048 Flying pins 10 mm Q7 Q10 with Z5161 Q Flying bracket Z5010 TV spigot with fixing plate Z5012 Pipe clamp for TV spigot Q7 Q10 with Z5161 Q Flying bracket Z5024 Loudspeaker stand adapter Q7 Q10 with Z5150 Q Swivel bracket Z5010 TV spigot with fixing plate Z5012 Pipe clamp for TV spigot Q7 Q10 with Z5175 Qi Horizontal bracket Z5010 TV spigot with fixing plate Z5012 Pipe...

Страница 14: ... directives of BGV C1 Rule for the Prevention of Accidents Z5172 Qi SUB Mounting plate Z5171 Qi Mounting plate Z5170 Qi Mounting adapter Z5160 Q Load adapter WLL 480 kg 1058 lb or 20 Qi1 loudspeakers aiming of a column by 1 1 1 2 or 1 4 detents Z5147 Rota clamp WLL 500 kg 1100 lb for a tube diameter up to 51 mm 2 Z5145 Ci Qi Mounting frame WLL 240 kg 530 lb e g nine Q loudspeakers ...

Страница 15: ...er and venue defined vertical profile Qi subwoofers can be integrated at any position within the array Three subwoofers can be mounted together in CSA mode where the centre QiCSA SUB radiates to the back For further information please refer to the TI 385 d b Line array design which is available for download at www dbaudio com Qi SUB QiCSA SUB Cardioid Subwoofer Array front view Qi SUB QiCSA SUB Ca...

Страница 16: ...vention of Accidents Flown Qi7 Qi10 array with Z5145 Ci Qi Mounting frame Z5160 Q Load adapter Z5147 Rota clamp Z5170 Qi Mounting adapter Z5171 Qi Mounting plate Z5172 Qi SUB Mounting plate Z5171 Qi Mounting plate Z5170 Qi Mounting adapter Z5160 Q Load adapter WLL 480 kg 1058 lb aiming of a column by 1 1 1 2 or 1 4 detents Z5147 Rota clamp WLL 500 kg 1100 lb for a tube diameter up to 51 mm 2 Z5145...

Страница 17: ...izontal bracket Z5053 Ci60 Ci90 Bracket connector Qi7 Qi10 with Z5161 Q Flying bracket Z5010 TV spigot with fixing plate Z5012 Pipe clamp for TV spigot Qi7 Qi10 with Z5175 Qi Horizontal bracket Z5010 TV spigot with fixing plate Z5012 Pipe clamp for TV spigot Z5044 MAX Bracket connector Z5054 Ci60 Ci90 Flying adapter Z5053 Ci60 Ci90 Bracket connector Z5020 Flying adapter 02 Z5161 Q Flying bracket Z...

Страница 18: ...t the sound propagation can be added to the model Up to fourteen flown arrays or subwoofer columns can be defined in a project file as single hangs or in pairs as well as a ground stacked subwoofer array consisting of up to twenty five stacks They can be freely positioned according to their intended application for example as main hang outfill delay line etc Position orientation coverage and aimin...

Страница 19: ...fined audience areas in a three dimensional view which can also be zoomed rotated and exported as a graphics file Up to four diffferent configurations and their mappings can be temporarily stored for comparison A comprehensive rigging plot with all necessary coordinates dimensions and weights is automatically generated for export and printing as well as a parts list detailing all the loudspeakers ...

Страница 20: ...o verify that the system performs within a predefined condition and can be used to report the system condition after a show d b Load monitoring on the other hand enables automatic and continuous impedance monitoring and along with Input monitoring is designed for incorporation within applications specified to the requirements stated in the International Standard IEC 60849 Sound Systems for Emergen...

Страница 21: ...r supply Switch mode power supply for 100 115 200 230V 50 60 Hz Mains connector PowerCon 2 D6 Remote network Remote network CAN Bus D6 Dimensions weight Height x width x depth 2 RU x 19 x 353 mm 13 9 Weight 8 kg 17 6 lb D12 Display ISP GR OVL A B LED indicators Liquid Crystal Display LCD Graphic display 120 x 32 Pixel D12 Controls POWER MUTE LEVEL Switch rotary encoder Function switches Loudspeake...

Страница 22: ...y coupled cabinets by reducing the low and mid frequency level CPL begins gradually at 1 kHz with maximum attenuation below 400 Hz providing a balanced frequency response when cabinets are used in arrays of two or more The CPL function can be set in dB attenuation values between 9 and 0 or a positive CPL value which creates an adjustable low frequency boost around 65 Hz 0 to 5 dB 100 Hz mode If th...

Страница 23: ...5 10 10 15 20 25 30 20 100 1k 10k 20k 5 0 5 10 10 15 20 25 30 20 100 1k 10k 20k Q1 and Qi1 standard and CUT single cabinet Q10 and Qi10 standard and CUT Q7 and Qi7 standard and CUT Q Qi and QiCSA SUB standard and 100 Hz Correction of HFC 5 0 5 10 10 15 20 25 30 20 100 1k 10k 20k Correction of HFA 5 0 5 10 10 15 20 25 30 20 100 1k 10k 20k ...

Страница 24: ...ommended A large sized Q Series configuration as shown on page 27 could consist of eight D12 amplifiers sixteen Q1 Qi1 loudspeakers and two Q7 Qi7 loudspeakers along with two subwoofer stacks comprising twelve Q SUBs or Qi SUBs with the two middle cabinets in CSA configuration and one J INFRA All the Q1 Qi1 loudspeakers are driven by eight D12 channels two Q7 Qi7 loudspeakers driven by one D6 ampl...

Страница 25: ... The Q Series configuration examples CAN Bus interface CAN Bus Laptop or PC running R1 R60 Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB Q1 Qi1 Q1 Qi1 Q1 Qi1 Q7 Qi7 D12 D12 Small line array configuration example ...

Страница 26: ...terface CAN Bus Laptop or PC running R1 R60 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB D12 D12 D12 Q SUB QiCSA SUB Small ground stacked configuration example CAN Bus interface CAN Bus Laptop or PC running R1 R60 Q1 Qi1 Q1 Qi1 Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB D12 ...

Страница 27: ... Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB Q SUB Qi SUB D12 D12 D12 D12 D12 D12 D12 D12 Q7 Qi7 Q7 Qi7 D6 J INFRA Q SUB QiCSA SUB QiCSA SUB QiCSA SUB QiCSA SUB Q SUB Q SUB Q SUB Large flown and ground stacked configuration example ...

Страница 28: ...6 D6 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q1 Qi1 Q7 Qi7 Q10 Qi10 Q1 Qi1 Q1 Qi1 Q SUB Qi SUB Q SUB QiCSA SUB Q SUB Qi SUB Q10 Qi10 Q SUB Qi SUB Q SUB QiCSA SUB Q SUB Qi SUB Q10 Qi10 Q1 Qi1 flown line arrays in left right configuration with Q7 Qi7 and Q10 Qi10 centre cluster Q10s Qi10s as fills and ground stacked Q Qi SUBs and QiCSA SUBs ...

Страница 29: ... SUB should only be aimed horizontally An additional cover should be positioned over the loudspeakers Qi loudspeakers with the Weather Resistant option are supplied with a fixed cable Cable type H 07 RN F 2 x 2 5 mm2 AWG 13 with a length of 5 5 m 18 ft as standard or length as required Special Colour SC option The paint finish of all loudspeaker cabinets and most accessories can be executed in alm...

Страница 30: ...specifying a rack be sure to allow extra depth 10 cm 4 is usually sufficient to accommodate the cables and connectors at the rear of the amplifier s When mounting amplifiers into a 19 rack cabinet provide additional support using shelves fixed to the inner sides of the cabinet or the mounting holes provided on the amplifier rear mounted rack ears do not just rely on fixing and supporting amplifier...

Страница 31: ... 4 2 115 100 V 15 A 2 1 D6 and D12 power consumption and power loss The power required from the mains supply and the waste heat produced by the amplifier power loss vary depending on the load impedance and the signal levels and characteristics e g speech music In practice the theoretical peak power consumption of a system will only be sustained for a short period of time Basing mains current and a...

Страница 32: ...access to different levels of control tailored to the operational demands For example simplified functionality for daily use and more complex functionality when multiple applications are required within one installation Input and Load monitoring coupled with automatic error messages allow installation operators to ensure the optimum performance at all times d b Remote interfaces Every d b amplifie...

Страница 33: ...uch as CUT HFA HFC or CPL R1 has extensive facilities for storing and recalling system settings allowing these to be repeated as and when required It is easy to adjust R1 project files for use with a different set of equipment at another location Password protection is available to restrict access R1 runs on PCs operating Microsoft Windows XP SP3 Vista SP1 71 A virtual machine enables R1 to run on...

Страница 34: ...oftware4 Z6118 000 R60 USB to CAN interface Z6124 000 R70 Ethernet to CAN interface Z6116 000 RJ 45 M Terminator Z6122 000 Bopla mounting clamp Z6123 000 Bopla mounting clamp upright Cables Z2298 xxx MC2 5SD Cable EP5 various length Z2299 xxx MC2 5 Cable NL4 various length Z2296 000 Extension adapter NL4 K3118 000 MC2 5SD Cable unterminated Racks E7211 000 Touring rack 2 RU 19 DD shock mounted han...

Страница 35: ... Mounting plate2 5 Z5054 000 Ci60 Ci90 Flying adapter2 Z5053 000 Ci60 Ci90 Bracket connector Q Qi accessories Z5161 000 Q Flying bracket2 Z5175 000 Qi Horizontal bracket Z5044 000 MAX Bracket connector5 Z5020 000 Flying adapter 022 Z5025 000 Flying adapter 032 Z5015 000 TV spigot for flying adapter 02 Z5010 000 TV spigot with fixing plate Z5147 001 Rota clamp Z5012 500 Pipe clamp for TV spigot Z50...

Страница 36: ...D1403 E 24 09 2012 d b audiotechnik GmbH www dbaudio com ...

Отзывы: