Section 2: Express Start Up
Danaher Motion
2
SS2000 D3 AND D6
SECTION 2: EXPRESS START UP
The following instructions define the minimum steps necessary to make your
Drive
operational.
Always disconnect the AC power to the unit and be certain the "PWR
ON" LED is OFF before connecting or disconnecting the motor leads.
FAILURE TO DO THIS RESULTS IN A SHOCK HAZARD.
Always operate the Motor and the Drive GROUNDED. Be sure to twist
together the wires for each motor phase. Six twists per foot is a good
guideline.
1. Check to see that the motor used is compatible with the drive. Refer to Section
4.4 for a list of compatible motors.
2. Set the correct current level for the motor being used per the instructions in
Section 4.5.
3. Select the appropriate step resolution and set the front panel switches as
described in Section 4.6.
4. Wire the motor per the "Motor Connections" description in Section 3.3.
5. Connect the power source to the AC input terminal strip. The terminal labeled
"L1" is line or hot, "N" is neutral or common and
"
"
is ground.
If the motor operates erratically, refer to Section 5, "Torque Versus Speed
Characteristics". Clockwise and counter-clockwise directions are properly
oriented when viewing the motor from the end opposite the mounting
flange.