Basic Configuration
05/2008
Danaher Motion
72
S200-VTS Product Manual
The following are optional parameters that can be set.
Parameter Function
EncOut
Sets the line count of the emulated encoder output. With 6-Step feedback the
emulated encoder output works by interpolating between the edges. So, at low
speeds signal quality will be poor.
EnInhibitCW
EnInhibitCCW
Enables the hardware over travel limits.
7.3.3
6-Step Velocity Mode
In 6-Step mode with Hall or Hall equivalent feedback, the drive can be configured to control
shaft velocity. But, because of the coarse resolution of 6-Step feedback the velocity bandwidth
and smoothness will not be as good as other feedback options.
To configure the drive for 6-Step feedback Velocity mode set the following parameters:
Parameter Value
CommMode
SetupS2-2 (Default value) with switch S2-2 set to the up position labeled,
6
on
the drive.
or
6-Step
CommOff
0 Degrees (Default value)
OpMode
Velocity
or
SetupS2-1 with switch S2-1 set to the up position labeled,
V
as shown on the
drive.
ARF0
ARF1
Single pole filters in the velocity loop forward path. Set to accommodate the
effects of mechanical resonance
KVI
Sets the velocity loop break out frequency from integral to proportional
compensation.
CmdSrc
Selects Analog, PWM, or Command variable for command.
CmdGain
Sets the command gain for the command input.
CmdOffset
Sets the command offset for the command input.
CmdF0
Sets the filtering on analog input command.
The following are optional parameters that can be set.
Parameter Function
EncOut
Sets the line count of the emulated encoder output. With 6-Step feedback the
emulated encoder output works by interpolating between the edges. So, at low
speeds signal quality will be poor.
EnInhibitCW
EnInhibitCCW
Enables the hardware over travel limits.