Danaher Motion
05/2008
Wiring the Drive
S200-VTS Product Manual
57
6.8
J5 – Serial Port Connector
J5 a 6-pin RJ-12/RJ-11 connector provides RS-232 serial communication to the drive. The RS-
232 transceiver is an industry standard RS-232 configuration using the MAX3221.
1
6
(J5 Connector view from
front of drive)
Pin Description
J5-1 No
Connection
J5-2 RX232
J5-3 I/O
RTN
J5-4 I/O
RTN
J5-5 TX232
J5-6 No
Connection
Mating Connector Information
RJ12/RJ11 – Phone Style -Standard RJ12/RJ11 plug
J5-1, J5-6
No Connection
These terminals are not used or connected to the drive.
J5-2
RX232
RS-232 receiver input to the drive. This terminal connects to the user's
RS-232 transmitter output.
J5-3, J5-4
I/O RTN
These terminals are the common/ground connection for the RS-232
serial port. The ground from the user's RS-232 needs to connect to this
terminal. Cable shielding is also connected to this point.
J5-5
TX232
RS-232 Transmitter output from the drive. This terminal connects to the
user's RS-232 receiver input.
CAUTION
Do NOT use the serial connector/cable when using an S200
SynqNet Series Drive. SynqNet cables, not a serial cable, should
be used for communication between the drive and SynqNet
motion controller. If you connect to an S200 SynqNet Series Drive
using a serial cable and select 'Serial' instead of 'SynqNet' as the
Communications Mode in the S200Tools Communication Wizard,
the drive will appear configured in the interface, but the SynqNet
Options tab will not appear under the Drive Setup options.