Appendix G – Regulatory Information 05/2008
Danaher
Motion
134
S200-VTS Product Manual
G.7
UL and cUL Conformance
The S200 drives are UL and cUL Recognized to UL 508C under UL File number E137798.
Consider the following points to ensure that final installation meets UL requirements:
The drive should be used within its specified ratings.
The drive should be mounted in the intended manner in an enclosure having adequate
strength and thickness with acceptable spacing for the end product classification.
The spacing from the exposed live-metal parts to the enclosure wall should be in
accordance with the requirements for the overall equipment.
These drives shall be used in a pollution degree 2 environment in order to comply with the
spacing requirements of UL 840 and UL 508C.
The UL temperature tests were done with a metal heat plate with overall dimensions, 6 in x
12 in x 1/8 in. The machine builder is responsible for ensuring adequate heat sinking
capability in the final installation.
The thermal protective device(s) provided integral to the motor drives were not evaluated
by UL.
The terminals are suitable for factory wiring only.
These motor drives have not been evaluated to provide solid-state overload or over speed
protection.
The DC models were evaluated by UL for use with an isolated power supply rated no more
than 150 V open circuit secondary voltage and 10 kVA secondary power. This combination
shall be maintained to satisfy UL requirements.