Specifications 05/2008 Danaher
Motion
10
S200-VTS Product Manual
3 SPECIFICATIONS
NOTE
Unless otherwise specified, the specifications are worse-case
limits and apply over the specified operating ambient
temperature and over the specified operating line voltage.
3.1
Drive Family Power
240 VAC Input
20-90 Vdc Input
S20260 S20360 S20660 S21260 S22460 S20330 S20630
Peak Output Current (RMS)
1
(0 to 50°C) Amb (A
RMS
) 4.5 9.0 18.0 30.0 48 9.0 18.0
Minimum Peak Current Time
Start from 0 A
RMS
(sec)
3.0
Continuous Output Current Convection
2
0 to 30° C amb (A
RMS
) 2.3 4.5 9.0 15.0
30.0 4.5 7.5
40° C amb (A
RMS
) 1.5
3.0
6.0
12.0
24.0
3.0
6.0
50° C amb (A
RMS
)
1.0 2.0 4.0 8.0 16.0 2.3 4.5
Peak Output Power (1 sec)
240 Vac (VA) 3 Phase
1500
3000
6000
10000
16000
-
-
240 Vac (VA) 1 Phase
1400
2600
5000
8000
-
-
-
120 Vac (VA) 1 Phase
700
1300
2500
-
-
-
-
75 Vdc (VA)
-
-
-
-
-
750
1500
Drive Continuous Output Power
240 Vac 3 Phase (W)
600
1100
2000
4000
8000
-
-
240 Vac 1 Phase (W)
500
900
1500
2500
3000
-
-
120 Vac 1 Phase (W)
250
6
450
6
750 - - - -
75 Vdc (W)
-
-
-
-
-
250
500
Continuous Motor Shaft Power @3000 RPM (Nominal Bus –10% 3 Phase/DC)
0 to 30° C amb (W) 3-ph
300
750
1500
2500
5000
180
315
0 to 30° C amb (W) 1-ph
300
750
1300
2200
2500
-
-
40° C amb (W)
200
500
1000
2000
4000
125
250
RMS Line Current at Continuous Output Power
240 Vac 3Phase (A
RMS
) 2.7 5.0 9.0
16 24
-
-
240 Vac 1 Phase (A
RMS
) 3.4 6.5 12
3
18
3
22
3
- -
120 Vac 1 Phase (A
RMS
) 3.4 6.5 12
3
- - - -
Maximum AC Line kVA (limits mains surges to drive)
AC Line kVA max
100
250
NA
+BUS Current With 75 VDC at Continuous Output Power
Average (A
DC
) NA
3.0
6.7
Inst. Peak (A
PeaK
) NA
12.7
25.5
Power Stage Diss. at
Icont, 40°C P
COnt
(W)
5
15 25 60 110 175 3 10
Shunt Regulator
Peak Power kW (500 mSec)
4.4
@36
Ω
6.4
@25
Ω
10
@15
Ω
10
@15
Ω
15
@10
Ω
Continuous Power (W)
440
@36
Ω
640
@25
Ω
1000
@15
Ω
1500
@15
Ω
2500
@10
Ω
NA
Maximum Regen Duty
Cycle (%)
10
@36
Ω
10
@25
Ω
10
@15
Ω
15
@15
Ω
15
@10
Ω
Regen Resistance (
Ω
)
25 – 50
25 – 50
12 – 50
8 – 50
8 – 50
NA