Danaher Motion
05/2008
Detailed Wiring Information
S200-CNS Product Manual
51
10.8 W
IRING
DINP5
AND
DINP10
As noted DINP5 and DINP10 are high speed opto-isolated input devices that do not have a
connection to a common rail. They are designed for 5 volt operation and the polarity of the power
supply used is critical for functionality. Not having a common rail connection the inputs can be wired
for sourcing or sinking according to the need of the application.
For systems desiring to use input voltages exceeding the 5V rating for DINP5 and DINP10 an
external current limiting resistor must be used. The resistor should be in series with the input line.
The following table indicates the recommended resistor values.
Supply Voltage
Resistor Value
3-6V No
Resistor
12V
470 Ohm ¼ Watt
24V
1200 Ohm, ½ Watt
DINP5
(DINP10)
S200 Position Node
Internal Equiv Circuits
Hi-Speed Opto-Isolator
Field Wiring
Customer’s Power Supply
5Vdc
J4-10
(J12-10)
J4-11
(J12-11)