Detailed Wiring Information
05/2008
Danaher Motion
50
S200-CNS Product Manual
10.7 T
YPICAL
W
IRING WITH
S
OURCING
S
WITCHES
The above diagram shows typical wiring for Sourcing switches. The Switches supply the source of
current through the S200 PN input. These devices may be solid state and are sometimes called
PNP devices.
Current drain for the inputs is identified in the following table.
Input Voltage (±)
Input Current (±)
4.0 volts
0.65 mA
5.0 volts
0.95 mA
12 volts
2.5 mA
24 volts
5.3 mA
30 volts
6.7 mA
+
-
Internal Opto-Isolators
DINP1
(Enable)
(DINP6)
DINP2
(DINP7)
DINP3
(DINP8)
DINP4
(DINP9)
S200 Position Node Internal Equiv
Circuits
Customer’s Power Supply
4 to 30Vdc
Field Wiring
Customer’s Switching
(May be Solid State)
J4-1
(J12-1)
J4-2
(J12-2)
J4-3
(J12-3)
J4-4
(J12-4)
J4-5
(J12-5)