Wiring 04/06
Danaher
Motion
2.2.2.4.
General Purpose Inputs
There are nine configurable General Purpose Inputs (GPI’s) on the P70360
drive. All the inputs share a common optically isolated bus (Pull Up/Down).
The common bus simplifies the wiring allowing a common point to connect
either sinking or sourcing input devices.
Typical Input Schematic
COMMON
OPTO
INX
Configuration Examples
Sourcing input device using
P7000 internal 5 VDC supply
Sourcing input device using
external supply (+3.5 - 24 VDC)
SW1
INX
19 (+5 VDC)
20 (Pull Up/Dn)
25 Common
SW1
INX
20 (Common)
J4
J4
DC
+
-
Sinking input device using
P7000 internal 5 VDC supply
INX
19 (+5 VDC)
20 (Pull Up/Dn)
25 Common
J4
SW1
Sinking input device using
external supply (+3.5 - 24 VDC)
SW1
INX
20 (Common)
J4
DC
+
-
Internal to Drive
Internal to Drive
Internal to Drive
Internal to Drive
SW1 Input device is shown as NORMALLY OPEN. It may also be configured
via the user interface as NORMALLY CLOSED.
NOTE
For voltages greater than 5 VDC (24 VDC max), install a current
limiting resistor in series with the input.
Size according to: R
CL
= (V
S
-5)100
12 Rev
D
M-SD-7AC-01