Danaher Motion
04/06
Appendix A
When installing the P7000 into its operating location, it shall be
ensured that any existing protective separation according to 5.2.18 of
EN50178 is maintained throughout the entire length of the circuit in
question. In installations the compliance for of the measures for
protective separation shall be checked by visual inspection.
Branch circuit protection consisting of a 240V, 20A circuit breaker was
relied upon during safety testing, adequate branch circuit protection
should be part of the final installation.
Motor cable shield must be connected to protective earth.
Consult the factory before using this product on a circuit protected by a
residual-current-operated protective device (RCD).
All covers shall be closed during operation.
The P7000 drives should be used within their specified ratings.
A.1.4 UL
REQUIREMENTS
The P7000 drives are UL and cUL Recognized to UL 508C under UL File
number E137798. The following points should be considered to ensure that the
final installation meets UL’s requirements:
The drive should be used within its specified ratings.
The drives shall be installed in an environment of Pollution Degree 2 or
better.
The devices shall be installed in compliance with the enclosure, and
mounting, spacing, and segregation requirements of the ultimate
application.
Suitable grounding means shall be determined in the end product.
These drives shall be used in a pollution degree 2 environment in order
to comply with the spacing requirements of UL 840 and UL 508C.
Phone jack is not for telephone connection.
The terminals are suitable for factory wiring only.
A UL Listed circuit breaker rated 240 V, 20 A was relied upon for
branch circuit protection during UL testing. A suitable branch circuit
protector should be considered when installing the device.
The short circuit protective circuit and/or overload protective circuit was
not investigated by UL.
A.1.5
EMC – COMPLIANCE WITH EN61800-3
Use in a domestic environment
WARNING
The products covered in this manual are of the
restricted sales distribution class according to IEC
61800-3. In a domestic environment this product
may cause radio interference in which case the
user may be required to take adequate measures.
M-SD-7AC-01 Rev
D
45