Danaher Motion
04/06
Using P7000Tools
4.4.5 COMMAND
CONFIGURATION
Command Signal Configuration
Here you can check the Step Resolution, Rotation Polarity, Enable Polarity, Stop
Rate, Rate Limit, and Velocity Limit.
Step Resolution
200 to
50,000 steps per motor revolution.
NOTE
When using a controller, set the drive resolution
equal to the controller resolution. This is particularly
important if there is position feedback to the
controller.
Step Input Filter
Check to enable low pass cutoff filter at 500 kHz to reduce
response to high frequency noise.
Rotation Polarity
Changes direction of motor rotation for a given input
command.
Enable Polarity
Active Open
Drive is enabled upon power up or external switch must
OPEN
to ENABLE drive.
Active Closed
External switch must
CLOSE
to ENABLE drive.
Stop Rate
Used by Motion Profile Generator to terminate a
programmed move.
Rate Limit
Global limit on ACCEL/DECEL in programmed moves.
M-SD-7AC-01 Rev
D
29