K4000 – List of Error messages
Messages
Explanation
No communication
Fatal error. No communication between the K
EY
P
AD
PC580 and
the drive. Check connecting cable.
Freq ctrl assigned on
T.Block
The speed control function has been assigned to T
ERMINAL
B
LOC
X2 in menu B and you try to change the speed from the K
EY
P
AD
Partition coding is missing
You selected the partition coding via the terminal block and no
selection is made. This message is displayed only after a
START command has been issued to the drive.
Partition coding through
T.Block
Partition selection is allocated to T
ERMINAL
B
LOC
X2 and you
want to select it using the K
EY
P
AD
Reversing assigned on
T.Block
The direction reversing function has been assigned to T
ERMINAL
B
LOC
X2 in menu B and you try to reverse direction from the
K
EY
P
AD
Access locked
The is locked by the KEY function on
T
ERMINAL
B
LOC
X2/47
AND
X2/48
Motor overload Im>Iref
The converter tripped because the motor current was higher
than the programmed reference current. This function is
programmed in menu C and a relay will be allocated to it. A time
delay can be allocated too.
Please wait before
resetting again
Display when trying to do a RESET when the intermediate DC
bus voltage is still higher than 30 VDC. Just wait for a while and
perform a new reset.
Converter temp.
to high !!!
The temperature of the heatsink exceed 75°C
Motor temperature
to high (PTC)
Overheating of the motor, detected by the PTC
Motor temperature
to high (NTC)
Overheating of the motor, detected by the NTC
External
Interlocks !!!
External interlock circuitry open
See T
ERMINAL
B
LOC
X2/39 – X2/40
Converter
overloaded
Displayed in case of short-circuit at the output or high current
peak exceeding the capacity of the drive.
Defect auxiliary
supply !!!
In case of problem with the auxiliary
power supply 24,
±
15 or 5 VDC
Mains out of
tolerance !! !
Displayed if your mains voltage is lower than 170 VAC
respectively higher than 530 VAC. Any value in between is
considered being within the tolerances
Failure on module No 1
The output power IGBT No1 is broken
Failure on module No 2
The output power IGBT No2 is broken
Failure on module No 3
The output power IGBT No3 is broken
Failure on Chopper module
The IGBT of the chopper is broken
Failure on Brake module
The IGBT of the braking chopper is broken
"Stop" circuit open !!!
When you try to START. Check connection X2/8 – X2/9 on
terminal block. This circuitry must be closed to START.
Switch to catch a spinning
motor OPEN
To catch a spinning motor. Check the circuitry X2/45 and X2/46
"Start/Stop” assigned to
Terminal Block
START function is allocated to T
ERMINAL
B
LOC
X2 and you tried
to start using the K
EY
P
AD
"Start/Stop” assigned
to keypad !!
START function is allocated to K
EY
P
AD
and you tried to start
using the T
ERMINAL
B
LOC
X2
Not allowed in STOP !!!"
You tried to reverse direction in STOP
Access forbidden
During WORK
The drive is in START mode and you try to access to Menu B or
C using the K
EY
P
AD
No errors recorded !!!
Displayed after
2ndF H
if the memory of failure is empty
S476-gb-0348
User Manual K4000
Page 43 / 48
Содержание ACOMEL K 4000
Страница 1: ...25 11 03 S476 gb 0348 K4000 USER MANUAL...
Страница 2: ...Empty page Page 2 48 User Manual K4000 S476 gb 0348...
Страница 48: ...Page 48 48 User Manual K4000 S476 gb 0348...