In the column
“Display”
is represented the text shown on the display
Display
Value
Key to
press
Comments
2ndF
B
0=F 1=GB 2=D 3=I 4=E
1
ENTER
Selection of the English language
Menu locking 0=B,C
0
ENTER
Access locking through X2/47-48
Start/Stop (choice)
0=PC560 1=T.Bl.?
0 ENTER
Assign the Start / Stop function to the
K
EY
P
AD
PC560
Speed display units
0=Hz 1=rpm ?
1 ENTER
Set the speed in RPM
Ð
Ð
Until you reach
Mains voltage
Ur (V) =
xxx ENTER
Input the mains voltage in volt
Partition selection
0=PC560 1=T.Bl. ?
0 ENTER
Assign the partition selection to the
K
EY
P
AD
PC560
Ð
Ð
Until you reach
PASSWORD: 616
ENTER
Give you access to the motor partitions
Partition No =
1
ENTER
Open partition 1
Number of poles =
x
ENTER
The number of poles, not of pairs
Motor power
P(kW) =
x ENTER
Input the max. power of the motor,
including overload
Iref source
0=PC560 1=Rtrip?
0 ENTER
Assign the input for the motor reference
current
I
REF
to the K
EY
P
AD
PC560
Motor nom. Current
Inom (A) =
x ENTER
Enter the nominal current of the motor.
Will be used to check other current inputs
Current accel/decel
Iacc (A) =
xxx ENTER
Input the acceleration current in A
Motor current
Iref (A) =
xxx ENTER
Input the nominal motor current in A
Acceleration time
10
ENTER
Set the acceleration time to 10 s
Deceleration time
10
ENTER
Set the deceleration time to 10 s
Ð
Ð
Until you reach
Us/Fs Pt. 1 (V/Hz)
Us = Fs =
ENTER
Enter the U/F characteristic. Start point
0V/0Hz is already stored.
2ndF
ENTER
The content of the partition inputs must be
confirmed by entering
2ndF ENTER
6. The START
Display show bloc G1
2nfF
F
Open the menu to input a speed
New frequency
(rpm) =
≤
1000
ENTER
Input a speed. We suggest 25% of the
maximum motor speed but maximum
1000 rpm
START
The motor will run at the inputted speed
STOP
The motor will stop
THE QUICK START IS NOW COMPLETED AND YOU CAN PROCEED TO THE FINAL
AND COMPLETE PROGRAMMING
Page 28 / 48
User Manual K4000
S476-gb-0348