DANA Diabecare II SR Скачать руководство пользователя страница 1

DANA Diabecare

II

SR 

User Manual

#다나2SR영문메뉴얼 rev.0  2007.7.3 5:43 PM  페이지1   001 Acrobat™ PDFWriter 300DPI 60LPI

Содержание Diabecare II SR

Страница 1: ...DANA Diabecare Ⓡ IISR User Manual 다나2SR영문메뉴얼 rev 0 2007 7 3 5 43 PM 페이지1 001 Acrobat PDFWriter 300DPI 60LPI ...

Страница 2: ...ality of life The welfare of the patient has been the cornerstone of our company s philosophy since 1979 when Dr Soo Bong Choi and his father Dr Hyun Choi designed their first insulin pump for patients in their diabetes center There are now more than 50 000 people throughout the world managing their diabetes with the DANA Diabecare line of insulin infusion pumps The DANA Diabecare Ⓡ IISR Insulin P...

Страница 3: ...DANA Diabecare Ⓡ IISR User Manual 다나2SR영문메뉴얼 rev 0 2007 7 3 5 43 PM 페이지3 001 Acrobat PDFWriter 300DPI 60LPI ...

Страница 4: ...es basal rates and the clock Setting a bolus Setting the basal rate Setting the clock Checking bolus doses basal rates and reviewing memory data Suspending the pump User Setting 3 Fillingandinsertinganewreservoir Changing the reservoir Preparation Filling the reservoir with insulin Instructions for use of DANA Easy SETTER Inserting the reservoir into the pump Connecting the infusion set to your pu...

Страница 5: ...our blood glucose level Calculating your bolus dosage Glucose meter related error messages and troubleshooting 6 Troubleshooting When hypoglycemia low blood sugar occurs When hyperglycemia high blood sugar occurs Problem Correction Action 7 Listofalarmsandaudiblesignals Low reservoir ERROR screen Daily remainder Daily max Low battery 8 Specifications symbols warranty General specifications Classif...

Страница 6: ...low 0 5 C or above 40 C 2 Atmospheric pressure below 500mmHg or above 1060mmHg 3 Humidity above 95 4 Exposure to excessive dust or a salty environment 5 Exposure to explosive gas 6 Exposure to direct sunlight 7 Environments where an electromagnetic field is generated by a medical device 6 The pump must not be used in the presence of intense electromagnetic fields such as those generated by certain...

Страница 7: ...sulinpump 1 The outside of the pump should be cleaned monthly 2 When cleaning the pump use a cloth moistened with water or a neutral pH detergent and wipe it with a dry cloth 3 Do not use thinner alcohol benzene or similar solvents Explanationof Warning Caution and Note Symbols ContentsoftheDanaDiabecare Ⓡ IISRInsulinPumpKit INSULINPUMP REMOTECONTROL RESERVOIR 6 INFUSIONSETS 6 DANAEASYSETTER 1 LIN...

Страница 8: ...Compartment Push the cover of the battery to the arrow direction to open Reservoir Window Remaining insulin amount can be visually verified here Blood Glucose Meter Test Port Test strips are inserted here for glucose monitoring Control Panel Contains the four buttons which are used to increase and decrease settings switch screens and select functions LCD Displays status of system features and syst...

Страница 9: ...ess Steel Stainless Steel Stainless Steel Polyurethane Softcannula Polyurethane Softcannula Stainless Steel Insertionangle 90 90 90 90 0 30 90 Disconnect No Yes Yes Yes Yes No Superline 90 Superline ST EasyRelease II EasyRelease Soft Release R Soft Release ST Note Infusion set specifications are as follows Note Product availability varies by country 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지7 001 Acrob...

Страница 10: ...doses TEMPORARY BASAL icon Choose the third icon person for temporary changes in basal rates for exercising or other events SET PROGRAM icon Choose the fourth icon sliding scale to set basal rates preset bolus doses and set clock Caution For accurate reading of the remaining battery charge check the initial display immediately after delivering a bolus Note Push any button while viewing the initial...

Страница 11: ...care provider or your sales representative Note The battery cover is correctly inserted and tightened when the battery cover is level with the insulin pump casing Note Do not attempt to change the battery while a bolus is in progress Note The battery has a shelf life of 3 years Please note best before date xx xxx before use WarningChange the battery in a dry environment to prevent water from enter...

Страница 12: ...SPLAY screen will appear 2 In the BASIC DISPLAY screen press three times consecutively to highlight the SET PROGRAM icon in figure 1 Then press figure 1 figure 2 3 The SET PROGRAM screen in figure 2 will appear You can select bolusor basalrate or clock 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지10 001 Acrobat PDFWriter 300DPI 60LPI ...

Страница 13: ...3 Press to go to the LUNCH BOLUS screen and repeat step 2 Press to advance to the DINNER BOLUS screen and repeat the step 2 4 After setting all of your meal boluses press to store the meal the meal bolus settings in the DANA memory 1 From the BASIC DISPLAY screen go to the SET PROGRAM screen In SET PROGRAM press when the BOLUShighlighted figure 1 The bolus setting screen will appear as shown in fi...

Страница 14: ... the SET PROGRAM screen In SET PROGRAM press when bolus icon is highlighted figure 1 The bolus setting screen will appear as shown in figure 2 Note Make sure to press after the bolus dose is set to save the setting Note You may confirm your bolus settings by using theCHECK REVIEW menu option see page 15 Note This setting is the amount of insulin that the pump will deliver the next time you bolus N...

Страница 15: ...RAM screen The BASAL RATE SETTING screen will appear as in figure 2 2 The Basal Profile appears in the lower left side of the screen Use to move between the 24 rates The corresponding chronological time will appear in the upper right corner Use the and buttons to change the basal rate for the highlighted time period 3 After basal rates are set press to save the settings in the DANA memory Note Bas...

Страница 16: ...d minutes Use and to make the desired changes figure 1 figure 2 3 After making the changes press to save the setting and return to the BASIC DISPLAY screen Caution You must set a m and p m correctly If the clock shows 03 00 p m and you want 03 00 a m you must press until the screen reflects your desired change Note The pump can be programmed in either 12 hour or 24 hour format 다나2SR영문메뉴얼 rev 0 200...

Страница 17: ...ar Press to move between basal profiles and confirm settings To review the previous meal bolus press 4 The MEAL BOLUS screen figure 4 will appear Press to move from one meal period to the next Press to review the history of the previous 500 boluses Note The CHK icon is used for reviewing both basal rates and bolus settings Note indicates check mode Note If your bolus and basal dose rate settings a...

Страница 18: ...ulin figure 6 Press to review the 500 previous Prime Amounts 7 Use and to review the Prime History including date time and amount figure 7 Press to review the 500 previous Carbohydrate amount 8 Use and to review the Carbo History including date time and amount figure 8 Press to review the Shipping info screen 9 In the Shipping Info fugure 9 press to return to the basic display Note Bolus History D...

Страница 19: ... tone and the screen will indicate the pump is suspended figure 3 선택 선택 4 To take the pump out of SUSPEND press You will hear an audible indicator and the BASIC DISPLAY will appear as shown in figure 4 Caution Always keep at least one power kit 2 batteries available for backup Note When you suspend the pump it will beep 3 times every 4 minutes to remind you insulin is not being delivered 다나2SR영문메뉴...

Страница 20: ... the key pad lock out function How to unlock see page 19 BUTTON SCROLL You can choose whether or not to utilize the button scroll function SOUND MODE You can choose the method of alert among sound DISPLAY SET see page 19 EXTENDED MENU see page 19 STRIP CHECK see page 20 EXIT Saves adjustment and returns to the previous level USER SETTING 1 HOUR DISPLAY TYPE 12 2 LOCK On 3 BUTTON SCROLL On 4 SOUND ...

Страница 21: ...e previous level DISPLAY SET 1 LCD ON TIME S 60 2 EL ON TIME S 10 3 LANGUAGE KO 4 EXIT EXTENDED MENU 1 EXTENDED BOLUS Choose whether or not to utilize the Extended Bolus function 2 UTILITY Choose whether or not to utilize the Utility function 3 NO CARBO MODE If the NO CARBO MODE wasselectedas Off a pop up window willdisplaytoperformthecarbohydratecountingfunction onceyou checkedyourBGlevelbytheDAN...

Страница 22: ...eck Strip into the Glucose Meter Port when the Strip Check displays figure 1 2 In case OK displayed the meter is normal figure 2 3 In case ERROR displayed the meter is abnormal figure 3 STRIP CHECK figure 1 figure 2 figure 3 STRIP CHECK ERROR STRIP CHECK OK 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지20 001 Acrobat PDFWriter 300DPI 60LPI ...

Страница 23: ... IISR Insulin Pump fast acting insulin reservoir infusion set DANA Easy SETTER linking screw alcohol swab etc Caution The reservoir must be changed every 3 days regardless of the amount left in the reservoir Caution The reservoir must be changed when there is less than 20u remaining Caution Always remember to change the reservoir and infusion set at the same time Caution Failing to warm the insuli...

Страница 24: ...3 5 Remove the needle from the reservoir and cover with the thin white reservoir cap figure 5 Please dispose of the needle properly 4 Place the clear needle protective cover back on the needle Remove any bubbles from the inside of the reservoir by gently tapping on the sides making the bubbles rise to the top of the syringe Gently push on the plunger to remove the bubbles at the top figure 4 figur...

Страница 25: ... the motor drive and linking screw of the pump and could result in the loss of insulin from the reservoir figure 2 figure 1 figure 3 Note The DANA Easy SETTER operates with the SOOIL 3 6V battery InstructionsforuseofDANAEasySETTER 1 Insert a battery into Easy SETTER as instructed below Open the battery compartment Insert a battery positive side up Close battery compartment 2 Insertasyringefilledwi...

Страница 26: ...n to highlight the PRIME icon as shown in figure 2 Then press 4 You will now see the FILLING SCREEN display as shown in figure 3 Use and to adjust the amount of insulin in cc s in the new reservoir placed in the DANA pump Then press figure 1 figure 2 figure 3 Note Remember to adjust this setting up or down to the amount you have actually placed in the reservoir Note The 2 5 cc is a preset default ...

Страница 27: ...n order to commence priming you must press thesecondtimewhilethescreendisplaystheword UP Note You will hear the pump beep for every 1 0 unit while priming is in progress Note The DANA Diabecare Ⓡ IISR insulin pump will allow 2 prime sequences every 12 hours 0 00 12 00 12 00 Note It is recommended that the pump be primed a minimum of 15 units Note You may pause the prime temporarily by pressing Pre...

Страница 28: ...umb and finger as in figure 3 Push the needle firmly into this tissue and secure with the adhesive dressing figure 1 figure 2 figure 3 figure 4 Note You should not feel pain when you touch the insertion area after the needle has been inserted You may feel some pain at the insertion site if the infusion set is not secured well to your body Note See page 32 for Soft Release ST inserting WarningDo no...

Страница 29: ... 90 into the skin The adhesive of the EasyRelease allows the needle to be fixed firmly in place Needle Cover Needle Hub Needle Needle Guide with Adhesive Site Connector Infusion Set Connector Connection Needle Collar Tubing Pump Connector Site Connector Cover Infusion Set Connector Cover 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지27 001 Acrobat PDFWriter 300DPI 60LPI ...

Страница 30: ...ry figure 2 2 Prime the infusion set by following the instructions on page 23 Air removal is complete when a drop of insulin appears at the end of the needle figure 3 3 Carefully remove the needle s protective cover figure 4 and the paper backing from the adhesive dressing figure 5 4 With your other hand pinch the tissue around the insertion site between your thumb and finger Push the needle firml...

Страница 31: ...Set Connector Cover from the Infusion Set Connector figure 12 3 Take pump out of SUSPEND see page 17 4 Before reconnecting program the pump to bolus 0 5 1 unit of insulin see page 39 and watch to ensure that a drop is visible from the Connection Needle tip figure 14 5 Gently slide the Infusion Set Connector into the Site Connector and pull the Collar back to secure the connection figure 15 5 Remov...

Страница 32: ...sive of the EasyRelease II allows the needle to be fixed firmly in place Needle Cover Needle Hub Needle Needle Guide with Adhesive Site Connector Infusion Set Connector Connection Needle Spring Clip Tubing Pump Connector Site Connector Cover Infusion Set Connector Cover 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지30 001 Acrobat PDFWriter 300DPI 60LPI ...

Страница 33: ...ab and allow to dry figure 2 2 Prime the infusion set by following the instructions on page 23 Air removal is complete when a drop of insulin appears at the end of the back side of needle figure 3 3 Carefully remove the needle s protective cover figure 4 and the paper backing from the adhesive dressing figure 5 4 With your other hand pinch the tissue around the insertion site between your thumb an...

Страница 34: ...ctor Cover from the Infusion Set Connector figure 15 3 Take the pump out of SUSPEND See page 17 4 Before reconnecting program the pump to bolus 0 5 1 unit of insulin see page 39 and watch to ensure that a drop is visible from the Connection Needle tip figure 16 5 Gently slide the Infusion Set Connector into the Site Connector by pressing lightly on the Spring Clips on either side of the Infusion S...

Страница 35: ...nly the cannula remains under the skin Needle Protective Cover for disposal Cannula Hub Teflon Soft Cannula Needle Guide with Adhesive Needle Hub Introducer Needle Bypass Needle Site Connector Infusion Set Connector Connection Needle Spring Clip Tubing Pump Connector Site Connector Cover Infusion Set Connector Cover 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지33 001 Acrobat PDFWriter 300DPI 60LPI ...

Страница 36: ...4 and remove the paper backing from the adhesive dressing figure 5 4 With your other hand pinch the tissue around the insertion site between your thumb and finger Insert the needle quickly at a 90 angle straight into the infusion site figure 6 Watch the Teflon soft cannula during insertion to assure that it goes in smoothly without kinking or crimping 5 Before withdrawing the Introducer needle you...

Страница 37: ...nfusion Set Connector Cover from the Infusion Set Connector figure 15 3 Take the pump out of SUSPEND See page 17 4 Before reconnecting program the pump to bolus 0 5 1 unit of insulin see page 39 and watch to ensure that a drop is visible from the Connection Needle tip figure 16 5 Gently slide the Infusion Set Connector into the Site Connector by pressing lightly on the Spring Clips on either side ...

Страница 38: ...care professional The needle is removed after insertion and only the cannula remains under the skin Needle Cover Site Connector Teflon Soft Cannula Needle Guide with Adhesive Needle Hub Introducer Needle Infusion Set Connector Connection Needle Spring Clips Tubing Pump Connector Site Connector Cover Infusion Set Connector Cover 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지36 001 Acrobat PDFWriter 300DPI 6...

Страница 39: ...n site figure 4 Watch the Teflon soft cannula during insertion to ensure that it goes in smoothly without kinking or crimping 4 Once the bottom portion of the adhesive has been fixed remove the top portion of the paper backing and apply the entire dressing Ensure that the cannula is firmly taped figure 5 5 To remove the Introducer Needle place one finger on each side of the Site Connector and one ...

Страница 40: ...ctor figure 15 3 Take the pump out of SUSPEND see page 17 4 Before reconnecting program the pump to bolus 0 5 1 unit of insulin see page 39 and watch to ensure that a drop is visible from the Connection Needle tip figure 16 5 Gently slide the Infusion Set Connector into the Site Connector by pressing lightly on the Spring Clips on either side of the Infusion Set Connector figure 17 5 RemovingtheSo...

Страница 41: ...se check expiration dates regularly and dispose of any expired accessories 5 Do not disconnect from your pump for more than one hour without discussing with your healthcare professional on how you should compensate for missed insulin Please remember that while disconnected from the pump no insulin is being infused Carefully monitor blood glucose levels during periods of disconnection and after rec...

Страница 42: ...n is highlighted as in figure 1 Then press The BOLUS screen will appear as in figure 2 3 Confirm the amount of insulin to be delivered in the bottom right corner of the BOLUS screen If the insulin dose is not correct you may make the desired adjustments to the bolus setting by using and Note Remember the adjustment will not change the default bolus setting It will only change the bolus that you ar...

Страница 43: ... Choose the first icon to access the NORMAL BOLUS screen the second icon to access the EXTENDED BOLUS screen and the third icon to access the DUAL PATTERN BOLUS screen Note Press once and the word BOLUS or BRFST LUNCH DINNER will be replaced by SELECT a second later In order to commence the bolus sequence you must press again while the screen is showing SELECT Note You will hear the pump beep for ...

Страница 44: ...igure 1 figure 1 ExtendedBolus 1 In the BASIC DISPLAY screen press until the BOLUS icon is highlighted as in figure 1 Then press 2 Use to highlight the middle icon and press figure 2 3 Use to toggle between BOLUS amount and BOLUS Period and make the necessary adjustments with and then press 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지42 001 Acrobat PDFWriter 300DPI 60LPI ...

Страница 45: ...LAY screen use to highlight the BOLUS icon and press The EXTENDED BOLUS STATUS screen will appear Note The time may be adjusted in 30 minute increments within the range of 30 minutes 8 hours Note The bolus amount may be set to any amount within the range of 0 bolus max 3 Use to toggle between STEP BOLUS and EXTEND BOLUS and BOLUS Period and make the necessary adjustments with and than press 다나2SR영...

Страница 46: ...e 1 figure 2 2 Press to invoke the cancellation prompt ExtendedBolusStatus 1 In the BASIC DISPLAY screen press until the BOLUS icon is highlighted as in figure 1 Then press 2 Thescreenwillshowhowmuchtimehaselapsedsincethestartofthe ExtendedBolus howmuchtimeisleftuntilthecompletionofthe ExtendedBolus amountdeliveredsofar andamountlefttobedelivered figure 1 figure 2 E E Note means Extended Bolus E 다...

Страница 47: ...y corresponds to the date and time of Extended Bolus conclusion Caution Infusion occurs on 4 minutes past the hour 8 minutes past the hour 12 minutes past the hour 16 minutes past the hour and so on in multiples of 4 Note Insulin is delivered every four minutes when the Dana IISR utilizes the extended bolus feature While in extended bolus mode insulin delivery will be halted during the following f...

Страница 48: ... during which the temporary basal rate will remain in effect This number indicates the desired increase decrease in basal delivery 3 Use to toggle between the number of hours and basal ratio and make the necessary adjustments with and figure 2 Note No temporary basal rate will take effect if you press while either the number of hours is set at 0 or the rate is set at 100 Note For instance a tempor...

Страница 49: ...he BASIC DISPLAY screen and press The TEMPORARY BASAL STATUS screen will appear as in figure 5 Time elapsed Time remaining Temporary basal rate 7 Press to highlight YES then press if you would like to cancel temporary basal The temporary basal rate in effect will be cancelled and you will be returned to the BASIC DISPLAY screen figure 5 Note Highlight NO and press at the cancellation prompt to ret...

Страница 50: ...ILITY MENU screen will appear as in figure 3 Note Select the leftmost icon for the Bolus Calculator middle icon for Temporary Basal and rightmost icon for Dose Automation figure 2 2 While in the UTILITY MENU screen press to access the BOLUS CALCULATOR screen figure 2 3 In the BOLUS CALCULATOR screen Use to move the cursor on CARBO to adjust the amount of Carbohydrate with the use of or button figu...

Страница 51: ...t of carbohydrates specified Indicates the amount of insulin remaining in your body from your previous bolus amount active insulin Indicates the calculated bolus amount figure 4 figure 5 5 Press twice to commence bolus delivery You will hear the motor run and the screen will show that a bolus is being delivered figure 6 Note You will hear the pump beep for every 1 0 unit while a bolus is being del...

Страница 52: ... indicate a temporary basal rate is in effect Note To confirm that temporary basal is in effect use in the UTILITY MENU screen to highlight the TEMPORARY BASAL icon and press The TEMPORARY BASAL STATUS screen will appear Note The percentage rate shown in figure 5 corresponds to the rate at which basal infusion will occur while temporary basal is active The percentage calculation is based on your r...

Страница 53: ... icon and press to access the TEMPORARY BASAL STATUS screen 4 Use to highlight YES and press to cancel temporary basal You will be returned to the BASIC DISPLAY screen upon pressing figure 2 figure 3 figure 4 3 Press to invoke the cancellation prompt Note If you do not wish to cancel choose NO and press at the cancellation prompt You will be returned to the BASIC DISPLAY screen upon pressing 다나2SR...

Страница 54: ...e 3 figure 4 figure 5 Note You may verify your bolus and basal rates through the CHECK REVIEW menu option Note The Daily Total can be set to any value within the range of 0 Daily Max Note The percentage rate can be adjusted within the range of 0 100 3 Use to toggle between Daily total and Bolus and Basal and make the necessary adjustments with and then press Note indicates pattern number 4 differe...

Страница 55: ...ump figure 1 figure 2 figure 3 figure 1 Bolus 2 While in the BOLUS SETTING screen select the proper insulin dose by using and The insulin dose appears in units in the bottom right hand corner 1 In the BASIC DISPLAY screen press until the BOLUS icon is highlighted as in figure 1 Then press Then press 1 Select the menu of connect icon at the basic menus display to synchronize the remote control with...

Страница 56: ...is being delivered Note Press once and the word BOLUS will be replaced by SELECT a second later In order to commence the bolus sequence you must press again while the screen is showing SELECT figure 3 Note Press or once to stop a bolus during delivery 1 Move to the program setting screen from the basic screen figure 1 press button once an icon of LOCK is displayed and then the LOCK icon will be di...

Страница 57: ... A disconnect icon will be displayed on the pump 1 From the BASIC DISPLAY go to the SET PROGRAM screen Press to highlight the CLOCK icon and press figure 1 The CLOCK SETTING screen will appear as shown in figure 2 2 Use to move between the year and month and date as well as hours and minutes Use and to make the desired changes 3 After making the changes press to save the setting and return to the ...

Страница 58: ...d on the end of the strip figure 5 figure 2 figure 3 Checkingyourbloodglucoselevel figure 1 figure 4 figure 5 Note The STRIP CODE range is between 0 and 49 You must use the code indicated on the DANA glucose strip packaging for accurate results Note If the strip is removed from the test port while the display screen appears as in figure 1 or figure 2 you will be returned to the BASIC DISPLAY scree...

Страница 59: ...The initial BOLUS CALCULATION screen will appear as in figure 9 Calculatingyourbolusdosage figure 9 Indicates your present blood glucose test result Indicates the amount of carbohydrates to be consumed prior to bolus delivery BG 100 CARBO 250 Note If you press you will be returned to the BASIC DISPLAY screen Note If you press while NO is highlighted you will be returned to the BASIC DISPLAY screen...

Страница 60: ... stop a bolus during delivery figure 11 Indicates the amount of insulin required according to your present blood glucose level Indicates the amount of insulin required to process the amount of carbohydrates specified Indicates the amount of insulin remaining in your body from your previous bolus amount Indicates the calculated bolus amount G 2 0U C 10 0U A 2 0U 10 0U 5 Press twice to commence bolu...

Страница 61: ...e professional Note Please refer to the following in the event of a measurement error WarningBlood Glucose meter precautions Do not use a bent or damaged strip Blood must not be applied to the strip prior to being prompted by the OBTAIN BLOOD screen The blood sample size must be sufficiently large to ensure an accurate reading Used strips cannot be reused Glucose testing must be conducted within t...

Страница 62: ...e instructions of your diabetes professional 4 Check your blood sugar level again in 15 20 minutes If it returns to normal no immediate action is needed and you may take the pump out of SUSPEND 5 If not refer to step 2 and retest in 15 minutes 6 If hypoglycemia appears prior to a meal consider bolusing while you consume your meal Themainsymptomsofhypoglycemia Headache and dizziness Sweating Shakin...

Страница 63: ...u may choose to use or modify temporary basal rates or decrease meal boluses prior to activity Increased physical activity Consult with your diabetes professional to adjust basal rates or meal boluses to more accurately reflect your current intake Eating less Please refrain from consuming alcohol Alcohol consumption Check and review your bolus history and basal rates Check with your diabetes profe...

Страница 64: ...ection of the infusion set to the pump and the infusion set connector Insulin leakage at infusion site disconnection site or connection to pump Change the infusion set Pinched or obstructed infusion set Check your blood sugar regularly and check with your diabetes professional to make sure that your bolus is properly calculated as well as your basal rates Incorrect settings Check to see if the pum...

Страница 65: ...er you administer a bolus dose The life span of the battery is usually 1 or 2 months but varies among users Some batteries are known to still show a full charge after two months even though they are low on charge To avoid any battery mishaps we recommend that you change the battery every two months or whenever there is a display problem with your screen Abnormal LCD Problem CorrectionAction Warnin...

Страница 66: ... the pump remove the infusion set and check your blood sugar then check the reservoir amount If less than 10 to 15 units of insulin remain in the reservoir replace it If this does not correct the error check for occlusion of the infusion set Visually check for any possible occlusion of the infusion set and take corrective measures unkink tubing check for air bubbles etc If this does not resolve th...

Страница 67: ...gs Meal Bolus Setting Basal Rate Setting Basal Profile Swiss Micro DC motor 12 seconds 3 6V DC Motor Bolus Duration for 1 Unit Power Supply Sleep Mode Screen Saver 4 minute intervals Dual microprocessors for continuous cross checking Energy Saver Basal Delivery Increments Integrated Circuit 7 Listofalarmsandaudiblesignals 8 Specifications symbols warranty 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지65 00...

Страница 68: ...e oxide Manufacture date Lot number Expiration date Use by date CE Marking SGS UK Do not re use Adhesive plaster Serial number Isolated patient connection IEC 60601 1 BF type Tubing length 43 inch 27 inch 1100 700 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지66 001 Acrobat PDFWriter 300DPI 60LPI ...

Страница 69: ... the pump by the user or any other person including but not limited to physical abuse of the product such as dropping or otherwise damaging the DANA Diabecare pump Failure to follow the manufacturer s instructions including those for storage transport or cleaning for the DANA Diabecare insulin pump This warranty does not cover batteries infusion sets cartridges or other accessories of the DANA Dia...

Страница 70: ...www sooil com IU E 21 rev 0 다나2SR영문메뉴얼 rev 0 2007 7 3 5 44 PM 페이지68 001 Acrobat PDFWriter 300DPI 60LPI ...