RECOMMENDED INSTALLATION HEIGHT 

From bottom edge of hand dryer above finished floor.

CLEANING AND MAINTENANCE 

Routine cleaning and maintenance is recommended every 12 months to ensure your hand 

dryer is running at optimal performance.

 

• Disconnect the electrical supply. 
• Remove the two cover-mounting screws. 
• Remove the casing. 
• Clean the interior of the dryer and remove any dust. 
• Check carbon brushes. If carbon brushes are worn, they must be replaced.  
  The estimated lifespan for carbon brushes is 580K activations. 
• Do not soak. 
• Use a damp cloth and mild cleaning solution. Never use cleaning  
  detergents with an abrasive effect. 
• Replace the cover. Do not overtighten the screws.

USER GUIDE 

•  No-touch operation. 
•  Shake excess water from hands. 
•  Place hands under the outlet to start operation. 
•  Rub hands lightly and rapidly. 
•  Stops automatically after hands are removed.

Men

1270 mm (50”)

Women

1194 mm (47”)

Children, 4-7 years

889 mm

(35”)

Children, 8-10 years

991 mm

(39”)

Children, 11-13 years

1092 mm (43”)

Children, 14-16 years

1194 mm (47”)

Wheelchair users

1016 mm (40”)

Содержание 346-347-348

Страница 1: ...USER MANUAL TURBO LOW NOISE HAND DRYER Model 346 347 348 250 251 254...

Страница 2: ...rm air speed output 7 Heating element switch 7 Adjustment of sensor range 7 Troubleshooting and corrective actions 8 Symptoms and corrective actions of first time installed hand dryers 8 Symptoms and...

Страница 3: ...00W adjustable Heating element protection Auto resetting thermostat turns circuit off at 85 C thermal fuse turns off at 142 C Drying time 15 seconds Stand by power 0 3 0 4W Sensor type Infrared self a...

Страница 4: ...ion If the power supply cord is damaged it must be replaced immediately Only qualified persons shall be permitted to replace the cord to avoid a hazard Disconnect the electricity supply cord according...

Страница 5: ...NEUTRAL to terminal N C Connect GROUND to terminal Make sure the main breaker is turned off Installation must be carried out by a qualified person in accordance with standards applicable in the count...

Страница 6: ...re worn they must be replaced The estimated lifespan for carbon brushes is 580K activations Do not soak Use a damp cloth and mild cleaning solution Never use cleaning detergents with an abrasive effec...

Страница 7: ...erclockwise to decrease air speed SENSOR RANGE ADJUSTMENT The sensor range adjustable between 100mm and 230mm Standard range 170mm 20mm Clockwise To increase sensor activation range Counterclockwise T...

Страница 8: ...n First ensure that the breaker supplying the dryer is opera tional If it is disconnect the power and remove the cover Replace PCB and IR sensor Taking suitable precaution to avoid shock hazard reconn...

Страница 9: ...rubber large 6 Motor 7 Motor rubber small 8 Blower housing lower 9 Heating element 10 Air outlet 11 LED panel 12 Air outlet bracket 13 Timer with IR sensor 14 Sensor bracket 15 Rubber bushing 4 reqd...

Страница 10: ...10 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV T 45 8641 5711 E info dandryer dk W dandryer com...

Отзывы: