80
•
Z-Trak2 features reference
Z-Trak2 3D Profiler Sensors
Trigger Input category
The Z-Trak2 Input features are used to configure external inputs.
Trigger Input features
Display Name
Feature & Values
Description
Device
Version
& View
Trigger Mode Selector
TriggerSelector
Selects the type of trigger to configure.
1.00
Beginner
Profile Trigger
LineStart
Selects the trigger that starts the capture of a
profile.
Variable Scan
VariableScan
Selects the Variable Scan trigger. Trigger Start
Source and Trigger Stop Source determine the
length of the scans.
Fixed Scan
FixedScan
Selects the Fixed Scan trigger. Scan Per Trigger
feature sets the number of scans to capture.
Trigger Enable
TriggerMode
Turns the selected Trigger On or Off.
1.00
Beginner
Off
Off
The selected trigger is off.
On
On
The selected trigger is on.
Scans Per Trigger
AcquisitionBurstFrameCount
Sets the number of scans to acquire when Fixed
Scan Trigger is enabled.
1.00
Beginner