When using the shaft encoder signals, the user can choose to connect to the opto-coupled inputs or
the RS-422/TTL inputs (which support a higher maximum pulse frequency). The imaging
application chooses which shaft encoder input to use via a board parameter (described following
the table below).
The following table describes the line trigger source types supported by the X64 Xcelera-HS PX8.
Refer to the Sapera Acquisition Parameters Reference Manual (OC-SAPM-APR00) for descriptions of
the Sapera parameters.
CORACQ_PRM_EXT_LINE_TRIGGER_SOURCE
The following table defines the trigger input source parameter values specific to the Xcelera-HS
PX8.
PRM Value
Active Shaft Encoder Input
0
Default
1
Use phase A
2
Use phase B
3
Use phase A & B
4
From Board Sync
5
Phase A & B,
shaft encoder after pulse drop/multiply output to Board Sync
6
Phase A & B,
camera line trigger output to Board Sync
7
Phase A & B,
camera line trigger output to Board Sync only while grabbing
Table 7: Line Trigger Source
CORACQ_PRM_EXT_LINE_TRIGGER_SOURCE full description relative to trigger type
and X64 Xcelera-HS PX8 configuration used:
PRM Value
X64 Xcelera-HS PX8
configuration & camera
input used
Input used as:
External Line Trigger
Input used as:
External Shaft Encoder
if
CORACQ_PRM_EXT_LINE_
TRIGGER_ENABLE = true
if
CORACQ_PRM_SHAFT_
ENCODER_ENABLE =true
0
Camera #1
Shaft Encoder Phase A
Shaft Encoder Phase A & B
1
Camera #1
Shaft Encoder Phase A
Shaft Encoder Phase A
2
Camera #1
Shaft Encoder Phase B
Shaft Encoder Phase B
3, 5, 6, 7
Camera #1
n/a
Shaft Encoder Phase A & B
4
Camera #1
From Board Sync
From Board Sync
Table 8: CORACQ_PRM_EXT_LINE_TRIGGER_SOURCE – Parameter Values