84
Sapera LT
X64-AN Quad User's Manual
Figure 44: CamExpert: Live acquisition window
If you have multiple cameras connected to the X64-AN Quad, select each board server in turn to
verify live grab from each camera.
Use the
File-Save
dialog to save this camera configuration file (*.ccf) with user entered
information. CamExpert provides information for each field based on the file originally loaded.
Modify the fields such as camera mode and board configuration, to describe the parameter setup.
Modify the file name and click Save. The ccf file is located in the default Sapera user folder.
Overview of Basic Timing Parameters
CamExpert only shows parameters applicable to the acquisition board and camera type. When
configuring parameters for a new camera start by selecting or entering the basic horizontal timing
parameters and pixel clock frequency as defined by the camera manufacturer.
Following is a brief overview of the basic timing parameters required for interfacing any camera.
Video Standard
: An analog camera is either RS170/NTSC or CCIR/PAL or Non Standard. The
group of Non Standard cameras covers all cameras that are not one of the basic TV standards. Video
capture of such cameras is only limited by the capabilities of the frame grabber hardware used.
Image Sensor readout
: The JAI CV-A11 output is full frame progressive scan video. Basic TV
standard video is interlaced.