Installation 

  

Review user interface controls, connections and mounting holes 

Front View  

1.

Reset button – front accessible USB port   

2.

12” Touch LCD display (

refer to appendix A for touch screen calibration

)

 

3.

Press control function keys as follows: 

Содержание Touch GEVA Series

Страница 1: ...GV 312T Touch Series GEVA Vision System Installation Manual 405 00046 00 September 9 2014 Revision 1 1...

Страница 2: ...rt of this manual and the related documentation are prohibited except with the express written consent of Teledyne DALSA Incorporated The information in this document is subject to change without noti...

Страница 3: ...shielded cables are used for external wiring A certificate of compliance is available upon request FCC This product has been tested and found to comply with the limits for a class A digital device pur...

Страница 4: ...l electronics to a potentially hazardous environment by opening the enclosure Doing so may cause serious damage User Service Warning With the exception of the externally accessible CFAST solid state d...

Страница 5: ...SB 14 Typical Configuration not using the PL USB 15 Software Getting Started 16 Directory Structure 16 The License Manager 17 iNspect Express Setup 18 Camera Selector 19 iDiscover 20 Sherlock Setup 21...

Страница 6: ...n of inspection solutions without requiring an external PC Runtime monitoring of inspections operator interface Runtime tool parameter editing Offline solution debugging using built in emulation The G...

Страница 7: ...t Express software 03 Sherlock software 04 Standard components ship with every GV 312T Component Description A VESA T VESA mounting hardware A PWR 24 DIN mountable 24VDC power supply A CAM XXXXXX XX G...

Страница 8: ...r interface controls connections and mounting holes 1 2 3 Front View 1 Reset button front accessible USB port 2 12 Touch LCD display refer to appendix A for touch screen calibration 3 Press control fu...

Страница 9: ...etwork adapter change settings interface Marking Default IP Connection LAN1 Dynamic IP Address DHCP enabled LAN network LAN2 Static IP Address 192 168 11 1 Camera Port 1 LAN left LED Off 10 Mbits s GR...

Страница 10: ...10 Installation Mount the Unit Panel Mount Locate the panel mounting clips included with the product Put the clamps into the holes located on the sides of the product as shown...

Страница 11: ...gasket included in the mounting kit around the inside back lip of the panel Place the GV 312T into the correct sized cutout on a control panel or frame and tightly screw the panel mounting clamps arou...

Страница 12: ...tible ARM This requires an optional mounting bracket A VESA T that should be purchased with the unit Take the bracket assembly and attach it to the back and sides of the product as shown below Make su...

Страница 13: ...with your Teledyne DALSA representative on applications requiring more than 4 cameras or high inspection speeds iNspect Express and Sherlock use different software drivers to interface GigE cameras i...

Страница 14: ...TES 1 Power connections not shown 2 Use A CAB GE X for camera Ethernet connections 3 Use A CAB GEVA FX for I O connections between camera and PL USB Setup Operator HMI iNspect Express shown Camera Net...

Страница 15: ...the PL USB module NOTES 1 Power connections not shown 2 Use A CAB GE X for camera Ethernet connections 3 Use A CAB GTP FX cables for camera power Setup Operator HMI Sherlock shown Camera Network I O...

Страница 16: ...Express C Program Files Teledyne Dalsa iNspect Express for VA Express bat iNspect Express Solution Files C Users Teledyne AppData Local Teledyne Dalsa iNspectExpressVA Solutions iNspect Express Emula...

Страница 17: ...e matches what you ordered before going any further Open the license manager from the start menu as follows Start All Programs Teledyne DALSA iNspect Express for VA License Manager OR Start All Progra...

Страница 18: ...se Manager 3 Open the Camera and Language Selector Program from shortcut and configure preferences Select GigE in the camera menu 4 Click on the iDiscover button to detect and configure cameras connec...

Страница 19: ...eatures for your application These features are peculiar to the iNspect Express software and are detailed in the software users manual From the camera selector tool you can launch both iDiscover and i...

Страница 20: ...rt IP segment at the top Click the Apply button to save changes Note Conflicting IP addresses will be designated by a red camera icon in the detected camera menu Select cameras to use in your iNspect...

Страница 21: ...e cameras connected to the system icon shortcut on the desktop 4 Run the Sapera CamExpert utility if you want to change settings in any of the cameras such as exposure strobe or white balance 5 Run th...

Страница 22: ...ng the Sapera CamExpert utility You can configure the camera to load either your saved settings or the factory settings at power up The preferred method is to save your settings to both the camera and...

Страница 23: ...not run saved programs Instead Sherlock will open a new investigation solution file The Sherlock application uses the settings stored in the camera or in camera configuration files You can also use S...

Страница 24: ...the Sherlock Drivers directory using Notepad If all cameras are the same type you can copy and paste the camera names in the correct order Or correct the references to Server0 and Server1 to match th...

Страница 25: ...AppData directory will be allowed all other system and program directories will be blocked The EWF is located in the C IPD Install Files directory The procedure to enable the filter is as follows 1 Br...

Страница 26: ...USB 2 0 1 front and 4 bottom I O Supported through PL USB module LED status 1 for Power Display TFT LCD 5 wire analog resistive XGA 16 2M colors Power 24V 60W Via screw terminal header on bottom Cool...

Страница 27: ...27 GV 312T Mechanical Dimensions Units in mm...

Страница 28: ...lication called PenMount Control Panel under Program files Execute this application Touch Screen Calibration In the Device tab tap the PenMount icon and tap configure or double tap the icon to open th...

Страница 29: ...vanced Calibration function improves the accuracy of calibration by using more involved engineering calculations Use this function only if you have tried the Standard Calibration and there is still a...