Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual
55
Teledyne DALSA
03-032-20117-01
Setting a Pixel’s FPN Coefficient
Sets an ind ivid u al p ixel’s FPN coefficient.
Camera Link Command
Parameter
Description
Notes
sfc x i
x
The p ixel nu m ber from
1
to
sensor
pixel count
i
Coefficient valu e in a range from
0
to
2047
(12 bit LSB).
Example
sfc 10 50
Setting Digital Offset
Sets the d igital offset. Digital offset is set to zero w hen you p erform FPN correction (
ccf
com m and ). If
you are u nable to p erform FPN correction, you can p artially rem ove FPN by ad ju sting the d igital offset.
Camera Link Command
Parameter
Description
Notes
sd o t i
t
Tap selection. Allow able range is
1
to
2
d ep end ing on cam era m od el, or
0
for all tap s.
i
Su btracted offset valu e in a range from
0
to
2048
w here
FPN Coefficient=
i
(12 bit LSB
Ju stified )
When su btracting a d igital valu e from the d igital
vid eo signal, the ou tp u t can no longer reach its
m axim u m u nless you ap p ly d igital gain u sin g the
ssg
com m and .
Example
sd o 0 100