56
Appendix A: GenICam Commands
Linea ML Color Cameras
Digital I/O Control Category
The camera’s Digital I/O Control category is used to configure the camera’s GPIO pins.
Figure 26: Digital I/O Control Panel
Digital I/O Control Feature Descriptions
Display Name
Feature
Description
View
Trigger Mode
TriggerMode
Determines the source of trigger to the camera.
Beginner
Internal
Internal Line rate is controlled with AcquisitionLineRate
feature.
External
External Trigger comes from CLHS (frame grabber) or GPIO.
Trigger Source
TriggerSource
Determines the source of external trigger.
Beginner
CLHS In
CLHS Source of trigger is from the frame grabber over
CLHS.
Rotary Encoder
Encoder Trigger source is from the two shaft encoder inputs.
Line 1
GPIO1 Trigger source is from Line 1 of the GPIO
connector.
Trigger Input Line
ActivationEdge
TriggerActivation
Determines which edge of a input trigger will
activate on
Beginner
Rising Edge
RisingEdge The trigger is considered valid on the rising edge of
the line source signal (after any processing by the
line inverter module).
Falling Edge
FallingEdge The trigger is considered valid on the falling edge.
Any Edge
AnyEdge The trigger is considered valid on any edge.
Содержание ML Series
Страница 16: ...14 The Linea ML Color Camera Linea ML Color Cameras Mechanical Drawings ML FC 08K10T 00 R ...
Страница 17: ...Linea ML Color Cameras The Linea ML Color Camera 15 ML FC 16K04T 00 R ...
Страница 18: ...16 The Linea ML Color Camera Linea ML Color Cameras ML HC 16K10T 00 R ...
Страница 30: ...28 Camera Performance and Features Linea ML Color Cameras Figure 10 Image with incorrect scan direction ...
Страница 80: ...78 Declaration of Conformity Linea ML Color Cameras Declaration of Conformity ...