Counter and Timer Control Feature Description
The following Counter and Timer Block Diagram describes the parameters along with their view
attributes and minimum camera firmware version required. The Device Version column indicates
which parameter is a member of the DALSA Features Naming Convention (indicated by DFNC),
versus the GenICam Standard Features Naming Convention (SFNC not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As Linea SWIR GigE capabilities evolve the device version will increase,
identifying the supported function package. New features for a major device version release will be
indicated by
green text
for easy identification.
Display Name
Feature & Values
Description
Device Version
& View
Counter Selector
counterSelector
Selects the counter to configure.
1.00
Expert
DFNC
Counter 1
Counter1 Select counter 1.
Counter Mode
counterMode
Selects the counter mode. The selected Counter is
either Active or Disabled. When Disabled, the
Counter can be configured.
1.00
Expert
DFNC
Off
Off The selected Counter is Disabled.
Active
Active The selected Counter is Enabled.
Counter Status
counterStatus
Returns the current state of the counter. (RO)
1.00
Expert
DFNC
Counter Idle
CounterIdle The counter is idle.
The CounterStartSource feature is set to off.
Counter Trigger Wait
CounterTriggerWait The counter is waiting for a start trigger.
Counter Active
CounterActive The counter is counting for the specified duration.
Counter Completed
CounterCompleted The counter reached the CounterDuration count.
Counter Overflow
CounterOverflow The counter reached its maximum possible count.
Counter Start Source
counterStartSource
Select the counter start source. Counter
increments from 0 to the value of the
counterDuration feature.
1.10
Expert
DFNC
Off
Off Counter is stopped.
Acquisition Start
AcquisitionStart Counter starts on the reception of the Acquisition
Start event.
Exposure Start
ExposureStart Counter starts on the reception of the Exposure
Start event.
Exposure End
ExposureEnd Counter starts on the reception of the Exposure
End event.
Frame Start
FrameStart Counter starts on the reception of the Frame Start
event.
Rejected Trigger
InvalidTrigger Counter starts on the reception of the Invalid
Trigger.
Line 1
Line1 Counter starts on the specified transitions on Line
1.
Line 2
Line2 Counter starts on the specified transitions on Line
2.
Timer 1 End
Timer1End Counter starts on the reception of the Timer 1 End
event.
Counter 1 End
Counter1End Counter starts on the reception of the Counter 1
End event.
Counter Start Line
Activation
counterStartLineActivation
Select the activation mode of the input line trigger
which starts the counter. This is only applicable
when the counterStartSource feature selects a
physical Line.
1.00
Expert