68
Appendix B: Trouble Shooting Guide
Resolving Camera Issues
Communications
No Camera Features when Starting CamExpert
If the camera’s CamExpert GUI is opened and no features are listed, then the camera may be
experiencing lane lock issues.
While using the frame grabber CamExpert GUI you should be able to see a row of status indicators
below the image area that indicates the status of the CLHS communications. These indicators
include seven lane lock status and a line valid (LVAL) status.
If the status for one or more lane locks is red, then there is likely an issue with the CLHS
connectors at the camera and / or frame grabber. Ensure that the connectors are fully engaged
and that the jack screws are tightened. Ensure that you are also using the recommended cables.
No LVAL
If the LVAL status is red and all lane locks are green, then there may be an issue with the camera
receiving the encoder pulses.
1.
From the Camera CamExpert > Digital I / O Control tab, select Internal Trigger Mode and
set the CamExpert > Camera Control tab Acquisition Line Rate to the maximum that will be
used.
2.
The trigger signal from the frame grabber will not be used and the LVAL status should now
be green. This will confirm the integrity of the image data portion of the CLHS cabling and
connectors.
3.
From the Camera CamExpert > Digital I / O Control tab, select External Trigger Mode.
4.
From the Frame Grabber CamExpert > Advanced tab, select the Line Sync Source to be
Internal Line Trigger and the Internal Line Trigger frequency to the maximum that will be
used.
5.
The trigger source is now being generated by the frame grabber and the LVAL status should
be green. This will confirm the integrity of the General Purpose I / O portion of the CLHS
cabling and connectors.
6.
From the Frame Grabber CamExpert > Advanced tab, select the Line Sync Source to be
External Line Trigger and select the Line Trigger Method to Method 2 under the same tab.
7.
From the Frame Grabber CamExpert > External Trigger tab, select External Trigger to be
enabled. If LVAL status turns red, check the following:
a.
Is the transport system moving such that encoder pulses are being generated?
b.
Has the encoder signal been connected to the correct pins of the I/O connector of the
frame grabber? See the XTIUM2-CLHS frame grabber user manual for details.
c.
Do the encoder signal levels conform to the requirements outlined in the XTIUM2-
CLHS frame grabber user manual?
Image Quality Issues
Vertical Lines Appear in Image after Calibration
The purpose of flat field calibration is to compensate for the lens edge roll-off and imperfections in
the illumination profiles by creating a uniform response. When performing a flat field calibration,
the camera must be imaging a flat white target that is illuminated by the actual lighting used in the
application. Though the camera compensates for illumination imperfection, it will also compensate
Содержание Linea HS Series
Страница 5: ...The Linea HS Monochrome Cameras 5 DECLARATION OF CONFORMITY 73 DOCUMENT REVISION HISTORY 74...
Страница 13: ...The Linea HS Monochrome Cameras 13 Responsivity QE Plots Note values measured using 8 bit 1x gain main array...
Страница 14: ...14 The Linea HS Monochrome Cameras Mechanical Drawings Figure 3 HL FM 08K30H 00 R Mechanical Drawing...
Страница 15: ...The Linea HS Monochrome Cameras 15 Figure 4 HL HM 16K30H 00 R Mechanical Drawing...
Страница 26: ...26 Camera Performance and Features Figure 7 Image with incorrect scan direction...
Страница 73: ...Declaration of Conformity 73 Declaration of Conformity...