Xtium2-CXP PX8 User's Manual
CamExpert Quick Start
•
29
Basic Timing Category
The Basic Timing category groups parameters such as camera type, the active image size, and
other settings related to basic timing.
Parameter Descriptions
The following table describes the CamExpert Basic Timing category of Sapera LT parameters.
Acquisition server notes, if applicable, indicate if parameter availability or supported values are
dependent on the selected frame grabber acquisition server and acquisition device.
Display Name Parameter
Description
Notes
Camera Type
Video source image type. Possible values are area scan or line
scan.
Not shown
for Bayer
servers
(areascan
only).
Color Type
Sets the color format of the input source.
Not shown
for RGB
servers.
Monochrome
servers
support:
Monochrome
Bayer
mosaic
Pixel Depth
Pixel depth (bits per pixel) of the input source.
Monochrome
servers
support:
8, 10, 12,
14 or 16 bit
Bayer and
Color
servers
support:
8, 10 or
12 bit
Data Lanes
Number of data lanes output by the camera.
Horizontal Active
(in Pixels)
Sets the horizontal camera resolution in pixels. This
corresponds to the visible part of the image from the camera.
Valid range depends on the acquisition module.
Vertical Active
(in Lines)
Sets the vertical camera resolution in lines per frame. This
corresponds to the visible part of the image from the camera.
Valid range is 1-16777215.
Not shown
for linescan
cameras.