58
•
Operational Reference
Linea Lite GigE Series Camera
Sensor TDI Mode
sensorTDIModeSelection
Selects how to combine the rows for processing.
Beginner
DFNC
Single Row Mode
TdiOff A single sensor row is output per line trigger.
High Sensitivity Mode
TdiSum Multiple sensor rows are synchronized and summed
together in the camera to increase the camera
responsivity.
Enhanced SNR Mode
TdiAvg Multiple sensor rows are synchronized and averaged
together in the camera to increase the signal to noise
ratio.
High Dynamic Range Mode
TdiHdr Multiple sensor rows with independent exposure times
are synchronized and combined together. This mode
can be used to produce a high dynamic range
demonstration image with enhanced contrast in dark
image regions.
Multi-Row Sensor Output
Mode
TdiMultiLine Two sensor rows are synchronized and output per
input line trigger. This enables processing of the
synchronized image rows by the host system. The
output image frame will consist of alternating sensor
rows starting with row one.
TDI Stages
sensorTDIStagesSelection
Selects the number of rows to sum/average in TDI.
Beginner
DFNC
1
Row1 Single row.
2
Rows2 Two rows summed/averaged together.
Line Spatial Correction
sensorLineSpatialCorrection
Set one line of delay between two sensor lines from
the sensor for Spatial Correction. Stop acquisition to
change.
Beginner
DFNC
On
On Turn on spatial correction.
Off
Off Turn off spatial correction.
Acquisition Line Rate
AcquisitionLineRate
Specifies the camera internal line rate, in Hz.
Beginner
Measured Line Rate
measureLineRate
Actual sensor line rate output.
Beginner
DFNC
ExposureMode
Sets the operation mode for the camera’s exposure.
Beginner
Timed
Timed The exposure duration time is set using the Exposure
Time feature and the exposure starts with a LineStart
event.
Trigger Width
TriggerWidth Uses the width of the trigger signal pulse to control the
exposure duration. Use the Trigger Activation feature
to set the polarity of the trigger. The Trigger Width
setting is applicable when the LineStart trigger is
enabled and a signal is selected as trigger source.
Exposure Alignment
exposureAlignment
Specifies how the exposure is executed in relationship
to the sensor capabilities and current line trigger.
Beginner
DFNC
Reset
Reset Sensor timing is reset to initiate exposure when a valid
trigger is received. Readout is sequential to exposure.
A trigger received during exposure or readout is
ignored since data would be lost by performing a reset.
Exposure Delay (in
μs
)
exposureDelay
Specifies the delay in microseconds (µs) to apply after
the LineStart event before starting the ExposureStart
event. Available when Exposure Mode is Timed.
Beginner
DFNC
Exposure Time (in
μs
)
ExposureTime
Sets the exposure time (in microseconds) when the
Exposure Mode feature is set to Timed.
Beginner
Gain Selector
GainSelector
Selects which gain is controlled when adjusting gain
features.
Beginner
System Gain
System Apply a digital gain adjustment to the entire image.
Gain applied after row gains.
Final digital gain = (Row Gain * System Gain)
Sensor Analog
SensorAnalog Sensor analog gain. Possible values are 1 or 2.
Digital Row 1
DigitalRow1 Gain applied to first sensor row.
Digital Row 2
DigitalRow2 Gain applied to second sensor row. Available only
when TDI Mode is HDR.
Preliminary