Some hardware changeable parameters of BOA2 cameras are available on the
“Application Setup” page. The main features are described below.
The Application Setup Page
1.
You can select which solution the camera loads at startup.
Note: This can also be
controlled from the script function.
2.
If the application doesn’t need the full sensor resolution, the image window can be
changed to ½ or ¼ size. This will have the added benefit of increasing
performance since there are less pixels to be processed.
Note: Partial resolution
modes may not be exactly ½ or ¼ vertical # of lines
3.
The image can be rotated or mirrored which can be useful if the camera is not
optimally mounted
Note: The camera must be rebooted by clicking the “Apply Configure” button before
changes take effect.
Version 4.3; 2017-11-20