26
IPS 10 000 – Firmware Versions 10.7.X| REV. 1.0.0 | © 2021 Dallmeier
7.2
DeaCtIVatION
The failure of a power supply module will be displayed cyclically by a system message (local and alarm
host) until the exchange. This feature can be disabled to avoid unnecessary repeated messages.
▶
Open the
Service Settings
dialog via
System
>
Service
>
Settings
.
Fig. 7-4
▶
Deactivate the defective power supply module if required.
▶
Confirm with
OK
.
The display of the corresponding system message is suppressed. After replacing the power supply mod-
ule this function is activated automatically, a resetting is not required.
7.3
eXChaNGe
If the device is powered by two redundant power supply modules, one can be exchanged during opera-
tion.
▶
Turn off the defective power supply module with the appropriate power switch.
▶
Remove the power cable.
Fig. 7-5
▶
Loose the screws at the top of the power supply module.