 Commissioning

10  Connections

Earthing/grounding connection (connecting thread M6)

Содержание Panomera S7

Страница 1: ...English Commissioning 005110 1 0 3 2015 09 15 S5 S8...

Страница 2: ...trademarks identified by are registered trademarks of Dallmeier electronic All trademarks identified by are trademarks or registered trademarks of the following owners JavaScript of Oracle Corporation...

Страница 3: ...Appropriate Use 10 5 6 Operation 10 5 7 Formation of Condensation 11 6 Requirements 12 6 1 Ambient Conditions 12 6 2 Power Supply 13 7 Maintenance 14 8 Limits of the System 15 9 Installation 16 9 1 In...

Страница 4: ...ice or software application Always follow the instructions notes and warnings and observe the technical specifications in the relevant product data sheet Keep all documents in legible condition and in...

Страница 5: ...on Requirements contains the most important steps for installing and calibrating the respective Panomera Multifocal Sensor System The target audience of the document is trained system integrators Conf...

Страница 6: ...lt in minor or moderate injury NOTICE NOTICE indicates practices for preventing property damage incorrect configurations or faulty operations For reasons of clarity and readability various text format...

Страница 7: ...opriate internal components may cause malfunctions damages and data loss and may result in the loss of warranty Modifications Do not make any modifications to the hardware or software that have not be...

Страница 8: ...andatory and must be fulfilled by all means Operating Conditions Unfavorable operating conditions may shorten the life of the device and may cause malfunctions damages and data loss and may result in...

Страница 9: ...nctions and features may require the purchase of an additional license 5 2 Transportation and Packaging Store the original packaging for later transportation Dallmeier is not responsible for any damag...

Страница 10: ...rdless of which part of the surveilled area an operator concentrates on and no matter when with Panomera all events are entirely covered at all times Therefore an incident can always be re constructed...

Страница 11: ...evented Condensation Inside the Housing Despite the built in pressure equalization element a sudden drop in temperature e g based on heavy showers or thunderstorms can cause water vapor moisture insid...

Страница 12: ...ect sunlight with strong heat emissions e g radiator with improper ambient temperatures near sources with strong radiation e g radio transmitters magnetic fields with corrosive surroundings e g gases...

Страница 13: ...er voltage electrical surge Danger of death or serious injury as well as damage to the device To ensure the safety of persons protection against dangerous contact voltages and to prevent damage to the...

Страница 14: ...bserve the following notes NOTICE Damage to the surface of the device Clean the housing with a soft dry and antistatic cloth Do not use detergents Do not use microfiber cleaning cloths Clean the front...

Страница 15: ...of the module transitions each camera module has to be optimally focused For this use the Lens Control dialog in the WebConfig user interface of the respective Panomera camera module the automatic ca...

Страница 16: ...For the installation of the wall ceiling bracket always use screws and anchors suitable for your wall ceiling type Ensure that the device is adequately secured during installation and operation with t...

Страница 17: ...www dallmeier com 17 Commissioning S5 S8 9 1 Installation on Wall Mount Bracket Adapter plate with two keyhole shaped slots 4 Hexagon socket head cap screw DIN 912 M6 16 4 washer DIN 125 A6 4...

Страница 18: ...18 www dallmeier com S5 S8 Commissioning 2 Slotted pan head screw with shoulder DIN 923 M6 4...

Страница 19: ...ww dallmeier com 19 Commissioning S5 S8 Attach the housing to adapter plate For this insert the slotted pan head screws into the keyhole shaped slots 2 Slotted pan head screw with shoulder DIN 923 M6...

Страница 20: ...20 www dallmeier com S5 S8 Commissioning Slide the housing forwards until the mini indexing plunger engages automatically Mini indexing plunger GN 822...

Страница 21: ...www dallmeier com 21 Commissioning S5 S8 Secure the housing with the supplied hexagon socket head cap screws 4 Hexagon socket head cap screw ISO 4762 M6x12...

Страница 22: ...Installation on Ceiling Mount Bracket Do NOT fully tighten the screws at this time Tighten the screws just enough finger tight so that the adapter plate can still be moved slightly for later housing...

Страница 23: ...www dallmeier com 23 Commissioning S5 S8 Loosen the slotted pan head screws on the bottom of the housing 2 Slotted pan head screw with shoulder DIN 923 M6 4...

Страница 24: ...24 www dallmeier com S5 S8 Commissioning...

Страница 25: ...www dallmeier com 25 Commissioning S5 S8 Carefully remove the sun shield from the housing...

Страница 26: ...26 www dallmeier com S5 S8 Commissioning Screw the slotted pan head screws on the top of the housing 2 Slotted pan head screw with shoulder DIN 923 M6 4...

Страница 27: ...www dallmeier com 27 Commissioning S5 S8...

Страница 28: ...28 www dallmeier com S5 S8 Commissioning Loosen the hexagon socket head cap screws of both plastic rails on the top of the housing 4 Hexagon socket head cap screw DIN 912 M6 10...

Страница 29: ...www dallmeier com 29 Commissioning S5 S8 Remove the plastic rails from the housing...

Страница 30: ...30 www dallmeier com S5 S8 Commissioning...

Страница 31: ...www dallmeier com 31 Commissioning S5 S8 2 Slotted pan head screw with shoulder DIN 923 M6 4...

Страница 32: ...www dallmeier com S5 S8 Commissioning Attach the housing to the adapter plate For this insert the slotted pan head screws into the keyhole shaped slots 2 Slotted pan head screw with shoulder DIN 923 M...

Страница 33: ...www dallmeier com 33 Commissioning S5 S8 Slide the housing forwards until the mini indexing plunger engages automatically Mini indexing plunger GN 822...

Страница 34: ...34 www dallmeier com S5 S8 Commissioning Secure the housing with the supplied hexagon socket head cap screws 4 Hexagon socket head cap screw ISO 4762 M6x12...

Страница 35: ...www dallmeier com 35 Commissioning S5 S8 Finally tighten both hexagon head screws adapter plate ceiling mount bracket 2 Hexagon head screw M6x12...

Страница 36: ...36 www dallmeier com S5 S8 Commissioning 10 Connections Earthing grounding connection connecting thread M6...

Страница 37: ...abling Optional data link fiber optic cabling Pin 1 48V DC 24V AC Camera Pin 2 48V DC 24V AC Heater Pin GND 48V DC 24V AC Camera Pin 3 48V DC 24V AC Heater Always observe the power supply requirements...

Страница 38: ...12 PureVideo version VP6 Architecture Maxwell Network 1000Mbps Gigabit Network Web browser Microsoft Internet Explorer latest version Software JavaScript enabled Microsoft ActiveX enabled Dallmeier Li...

Страница 39: ...ons in the Panomera documentation Configuration Quick Guide 11 3 Establishing the Connection Panomera WebConfig Ensure that your PC web browser can establish a connection to your Panomera Multifocal S...

Страница 40: ...y The factory default admin password of each Panomera module is 3 NOTICE Risk of access and misuse by unauthorized users Change the factory default admin password as soon as possible Common settings U...

Страница 41: ...ive product data sheet Heater Max 60W Connection Hirschmann CA 3 GS mating connector Hirschmann CA 3 LD Mechanical Data Construction material Aluminum Finish Powder coating grey white RAL 9002 Weight...

Страница 42: ...42 www dallmeier com S5 S8 Commissioning 13 Dimensions 306mm 12 05 186 mm 7 32 370mm 14 57 186 mm 7 32 370 mm 14 57 306mm 12 05 40 mm 1 57 70 mm 2 76 62mm 2 44 Adapter plate...