Rev. 1.0.0 | © 2020 Dallmeier | www.dallmeier.com
MDF5250HD-DN Commissioning
9
Installation and Commissioning
The installation and commissioning of the device may only be carried out by qualified personnel.
Depending on the mounting technique, the following tools/accessories are required to install the device:
•
4× mounting screw (Ø 3 mm) + suitable anchors/dowels (if necessary) for fixing the encoder unit
or
2× mounting screw (M3)
•
2× mounting screw (Ø 4 mm) + suitable anchors/dowels (if necessary) for fixing the supplied U-shaped mounting bracket for the lens-sensor unit
or
1× common bracket/tripod with standardized tripod screw (UNC 1/4"-20)
•
Suitable screwdrivers for used mounting screws
WARNING
Personal injury caused by falling device or collapsing supporting structure
Risk of death or serious injury
➡
Before installing the device, follow the manufacturer’s instructions regarding the maximum permissible carrying capacity of the
supporting structure (e.g. ceiling or wall).
➡
When installing the device, only use screws and, if necessary, anchors/dowels that are suitable for the respective type (construction
material) of the supporting element, such as for example:
•
Plastic screw anchors for use in solid masonry materials (concrete/brick)
•
Gravity or spring toggle anchors for use in drywall systems (plasterboard)
➡
Strictly observe the locally applicable regulations (regional and country-specific legal requirements) regarding the mandatory measures
for securing the device against falling during mounting/dismounting, operation and maintenance of the device.
Before mounting the device, observe the maximum available cable length between the lens-sensor unit and the encoder unit.