background image

IPS 10 000 

26

 www.dallmeier.com 

10  Connections

The connections can differ depending on the ordered equipment 

 

or variant. 

A         B          C           D  E F  G H        I     J       K         L  M      N  O  P  Q  R               S

A

Power Supply Unit 1

 

IEC C14 socket, 115/230 V AC ±5%, 50/60 Hz

K

Video OUT Interface

 

DVI-D, Dual Link (24 + 5), 1920 × 1080 

(configuration)

B

Power Supply Unit 2

 

IEC C14 socket, 115/230 V AC ±5%, 50/60 Hz

L

Ethernet Interface 2

 

RJ45, 10/100/1000 Mbps (optional)

C

Power Supply Unit 3

 

IEC C14 socket, 115/230 V AC ±5%, 50/60 Hz 

(optional)

M

USB Interface

 

2× USB 3.0, type A

D

Relay OUT (1-4)

Weidmüller socket, 8 pins, max. 12 V DC / 24 V 

AC / 0,5 A, 150 mOhm

N

USB Interface

 

2× USB 2.0, type A

E

Contact IN (1-4)

Weidmüller socket, 6 pins, only for switch /  push 

button (dry contact)

O

Ethernet Interface 1

 

RJ45, 10/100/1000 Mbps

F

Keyboard

 

PS/2, purple

P

Microphone IN

 

3.5 mm phone jack, red, 4.3 kOhm, 2.828 V

pp

G

Mouse

 

PS/2, green

Q

Audio OUT

 

3.5 mm phone jack, green, 1 kOhm, 

2.828 V

pp

H

USB Interface

 

4× USB 2.0, type A

R

AUX / Line IN

 

3.5 mm phone jack, blue, 16 kOhm, 

2.828 V

pp

I

Video OUT Interface

 

2× DisplayPort (configuration)

S

SATA Interface

 

RAID controller board for 

 

JBOD storage extension (optional)

J

Serial Interface COM 1

 

D-SUB, 9 pins, 1× RS232

Содержание IPS 10 000

Страница 1: ...005843 1 0 3 2018 12 19 IPS 10 000 Commissioning English...

Страница 2: ...ss negligence of the manufacturer Dallmeier electronic GmbH Co KG Bahnhofstr 1 93047 Regensburg Germany www dallmeier com info dallmeier com All trademarks identified by are registered trademarks of D...

Страница 3: ...6 32 1 2 2 2...

Страница 4: ......

Страница 5: ...3 Transportation and Packaging 14 Warranty 14 Appropriate Use 14 Approvals Certifications 15 Note USA 15 6 Requirements 16 7 Rack Installation 18 Dimensions 18 Preparation 19 Mounting 20 8 HDD Mountin...

Страница 6: ...scope of delivery in a printed form and or on a digital medium Read all documents included in the scope of delivery carefully and thor oughly before using the device Always follow the contained instru...

Страница 7: ...arget audience of this document is trained system integrators Other Applicable Documents Specification The document Specification contains detailed technical data features and characteristics of the d...

Страница 8: ...ates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUT...

Страница 9: ...s documentation Instructions are indicated by arrows Bold and italic expressions generally indicate a control element on the device switches or labels or on its user interface buttons menu items Bold...

Страница 10: ...es must be followed Regulations The use of video and audio surveillance systems is in general strictly regulated Inform yourself about the currently valid laws and regulations regarding data worker an...

Страница 11: ...to 8 hours until the device has reached room tem perature before commissioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices prote...

Страница 12: ...e sales partner responsible for your area Burnt Smell If you notice burnt smell or a formation of smoke coming from the device immediately disconnect it from the power supply pull out the power plug C...

Страница 13: ...ounting screw six lobe 6 32 UNC 5 32 2 Key for HDD tray cam lock 2 Power cord IEC 60320 C 13 connector to European plug 1 Weidm ller plug in connector B2L 3 50 14 180 SN BK 1 Documentations printed an...

Страница 14: ...terms and conditions valid at time the contract was signed shall apply Appropriate Use The appliance IPS 10 000 combines the proven and extended VideoIP software SMAVIA Recording Server with a reliab...

Страница 15: ...suant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfer ence when the equipment is operated in a commercial environment This equipment gen...

Страница 16: ...th limited access device or server room Ensure that the rack is installed in a stable way and is suitable to with stand the weight of the mounted devices Device Installation Install heavy devices at t...

Страница 17: ...ply UPS to protect the device from voltage spikes and to keep it in operation in case of power failure NOTICE Danger due to difficult separation from the circuit The plug of the supply line serves as...

Страница 18: ...the device may only be carried out by qualified personnel The following tools are needed for the installation Cross recess screwdriver 5 mm Star screwdriver T10 Dimensions 442mm 17 4 533mm 21 0 133mm...

Страница 19: ...9 Preparation Use the 19 rails included in the scope of delivery Shorten the rails if necessary Align the guidance of the rails to the rear side Align the rails according to the depth of the rack Fast...

Страница 20: ...CAUTION Risk of injury due to heavy weight Ensure that at least two persons are available for the installation of the device holding mounting Insert the device with the rails into the guidances Insert...

Страница 21: ...com must not be formatted or partitioned should have the same capacity number of sectors should be from the same production series with identical firmware NOTICE Risk of damages Ensure that the devic...

Страница 22: ...he bottom side of the HDD Ensure that the connections of the HDD are positioned at the rear side of the HDD tray Ensure that HDD and HDD tray are flush at the rear side Mount the HDD tray on the HDD w...

Страница 23: ...o operation during the first start of the device Depending on the number and pcapacity of the built in hard disks various messages and dialogs are displayed during the first start and initialization C...

Страница 24: ...1 2 3 4 8 7 6 5 A B C D E F G A Hard disk drive 1 3 5 HDD on HDD tray B Power blue Always lights up while the device is switched on C Record green Indicates the recording activity hard disk activity o...

Страница 25: ...HDD is defective HDD is not active and OK RAID spare HDD HDD is in recovery process RAID HDD is not mounted C Line for status messages D Version number SMAVIA Recording Server E F G Status power supp...

Страница 26: ...B Interface 2 USB 3 0 type A D Relay OUT 1 4 Weidm ller socket 8 pins max 12 V DC 24 V AC 0 5 A 150 mOhm N USB Interface 2 USB 2 0 type A E Contact IN 1 4 Weidm ller socket 6 pins only for switch push...

Страница 27: ...eidm ller 8 Pins Pin Assignment Triggering event Type 1 2 Relay 4 Configurable function Normally open 3 4 Relay 3 Configurable function Normally open 5 6 Relay 2 Configurable function Normally open 7...

Страница 28: ...user interface is displayed in the initial state as soon as the start is complete Local Login In the initial state a login without password is possible The rights of the Administrator group are valid...

Страница 29: ...meier com 29 Click the Login button The Recorder Login dialog is displayed Click Later to login without changing a password The configuration interface is displayed Refer to the corresponding Configur...

Страница 30: ...pprox 5 minutes The IP address of the device default 192 168 2 230 can be changed without login using the PService3 software Remote Login In the initial state a remote login is possible using the seri...

Страница 31: ...45678 as the Password Confirm with Login The configuration interface is displayed The configuration interface is compressed for narrowband connections before transmission if the Slow Network check box...

Страница 32: ...or configuration AUX Line IN 1 3 5 mm phone jack Microphone IN 1 3 5 mm phone jack for intercom license 003801 required Audio OUT 1 3 5 mm phone jack for intercom license 003801 required USB 2 USB 3 0...

Страница 33: ...ical Data Dimensions W H D Approx 483 133 533 mm 19 0 5 3 21 0 inches Weight Approx 20 kg 44 lbs with 8 HDDs Ambient Data Temperature 5 C up to 40 C 41 F 104 F Recommended temperature 20 C up to 25 C...

Страница 34: ...Ensure that all supply lines are disconnected from the supply circuit CAUTION Danger of explosion if battery is incorrectly replaced Replace and discard the battery of the main board in accordance wit...

Страница 35: ...IPS 10 000 www dallmeier com 35 Notes...

Страница 36: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 941 87 00 0 Fax 49 941 87 00 180 www dallmeier com info dallmeier com...

Отзывы: