4 INSTALLATION PROCEDURE
4.1 Pre-Installation procedure
4.1.1 Incoming Inspection
1. Inspect the exterior of the shipping box(s) for any evidence of damage that can affect units inside. If damage
is found file a claim with the carrier. Inform Dali customer service.
2. Unpack each box, check for damage, and verify content using the packing slip. If damage is found, or parts
are missing, file a claim with the carrier. Inform Dali customer service.
4.2
tHost™
Installation
4.2.1
tHost™
Mounting
The
tHost™
is a one rack unit (1RU) high assembly that mounts inside a standard 19” equipment rack. In
case the unit is to be mounted in a 23” equipment rack, proper adapters shall be used. The mounting tabs on the
t
Host™ can be rotated or relocated to provide front or rear access as well as wall mounting.
•
Ensure that easy access to the RF, Fiber, DC (back of the unit), and Network (front of the unit) connectors
is available.
•
Use provided screws to attach the
tHost™
to the equipment rack. If wall mounting the unit, appropriate
mounting hardware should be used.
4.2.2 Cables Installation
Ensure that all RF cables and attenuators used to connect the base station(s) to the
tHost™
are tested and
Insertion Loss and Return Loss information logged.
Ensure continuity and quality of the optical fiber cables that connect the
tHost™
with
t43™
s. Conduct necessary
testing or obtain valid test data. Professionally clean the fiber connectors prior to connecting to
tHost™
optical
interfaces. Refer to Section 7.2 for an optical connector cleaning procedure.
•
Connect and secure ground wire to ground stud mounted on
tHost™
back panel. A #6 copper wire
connected to included ring lug must be furnished by installer to provide a low resistance link between the
tHost™
and earth ground source.
•
Connect and secure RF cables to Band 1, 2, 3 and 4 Tx/Rx (or Tx and Rx) coaxial female SMA-type
connectors, all located on the
tHost™
front panel.
•
Connect fiber cables (patch cords) with LC/UPC type connectors to pluggable LC SFP optical
transceivers (maximum 6) located on the
tHost™
.
Note: SFP connections using optical cables (patch cords) with LC/APC connectors are not supported.
•
Connect and secure DC cable to the
tHost™
DC connector. The
tHost™
is powered by n48
VDC. This power shall be provided through a fuse panel, and protected with 5A GMT fuse.