4.3.2.3 Fiber Cable Installation
The DRU is equipped with two chassis mount, outdoor, industrial SC adapters, each providing waterproof
bidirectional optical interface for band 1 and band 2: Tx, main Rx, diversity Rx (for version with UL diversity), and
M&C signals. Second optical interface enables daisy-chain networking with other DRUs.
The DRU ships with mating outdoor industrial SC cable connectors (please refer to Figure 4-6), that installer
should assemble onto environmentally hardened, single mode optical fiber cable, used for interface between the
remote unit and an Outdoor Plant splice tray.
Figure 4-6 Outdoor Industrial SC Adapter and SC Cable Assembly Connectors
9. Remove the DRU optical connector dust cap, and fiber cable connector dust cap.
10. Align and insert the plug end of the cable connector into the DRU optical connector receptacle. Lock the
cable connector in place by turning connector clockwise.
11. Route the fiber cable to the Outdoor Plant box. Secure optical cable using standard practices.
12. Repeat the steps 5 to 7 if second optical cable installation is required to establish daisy-chain connection
of this DRU to another DRU.