![DALBO MAXIROLL 1030 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/dalbo/maxiroll-1030/maxiroll-1030_manual_503821029.webp)
MAXIROLL
Page 29
Mounting
1.
Fit new gaskets (pos. 5+6+7+8+9) in upper part and collar shoe. Remember to
check gaskets are facing the right way.
2.
Lubricate thread in upper part (pos. 3) with oil.
3.
Fit upper part (pos. 3) on ram shaft.
4.
Fit collar shoe (pos. 4) and screw on lock nut, secure with Loctite. Ensure that
thread is absolutely clean and free of oil or other impurities before applying
Loctite. Do not fill with oil for 12 hours after use of Loctite.
5.
Lubricate outer collar shoe gasket in contact with cylinder tube and inside of
cylinder tube with oil, push ram into centre position.
6.
Fit upper part onto cylinder tube and tighten.
7.
Fit cylinder (see ”
Replacing extend cylinder for folding side sections
”).
Replacing raise/lower cylinder on main frame
Fig. 25
Extend roller and relieve pressure on
raise/lower cylinder (A).
1.
Disconnect hoses from cylinder
2.
Support cylinder
3.
Remove split pins in pins, remove pins
4.
Remove cylinder
5.
Fit new or repaired cylinder
Activate raise/lower cylinder after fitting until cylinder shows movement. Reverse
cylinder until it returns to start position. Move cylinder backwards and forwards
several times. Fully extend cylinder several times to bleed system.
Ensure no personnel are within the extension radius of the side sections.
A
Содержание MAXIROLL 1030
Страница 1: ...MAXIROLL EN 1030 1230 Serial no 100 XXX ...
Страница 2: ......
Страница 38: ...MAXIROLL Page 38 Hydraulic diagram Fig 35 ...
Страница 39: ...MAXIROLL Page 39 Fig 36 Accumulator 1 0 L Non return valve single Volume distribution valve ...
Страница 40: ...MAXIROLL Page 40 Fig 37 Ball stop valve Accumulator Accumulator Accumulator Accumulator Accumulator ...
Страница 41: ...MAXIROLL Page 41 Fig 38 ...
Страница 42: ...MAXIROLL Page 42 Spare parts ...