Mount Display
For Multi-Section Displays – See
.
1.
Lift the display into position on support
structure. Refer to label at lift eyes for
information.
• Maintain a 55-degree or greater angle
between display and lift straps.
• Do not adjust or remove lift eyes.
• Do not lift display in wind speeds greater
than 20 mph.
2.
Weld or bolt ALL T-clips to support structure.
Note:
T-clips can be adjusted within the
guidelines of the label located at each
T-clip.
Angle must be
greater than 55°
L
T-CLIP CAN BE ADJUSTED BUT MUST FALL BETWEEN LINES
Connect Power
Note:
GT6X displays have multiple power
entrances depending upon the display
length.
1.
Route conduit from the main distribution
panel/disconnect to each display power
entrance. In GT6X displays, each display
section has a power entrance and requires a
dedicated circuit
2.
Remove the four screws that attach the power
entrance access door.
3.
Connect conduit to the 1
1
/
4
″ Myers hub at the
left of the power entrance box.
4.
Feed power cable from the conduit into the
power entrance box.
5.
Connect primary power lines to appropriate
taps in enclosure – refer to label on enclosure
for wiring diagram.
6.
Reinstall power entrance cover.