background image

Large Matrix Galaxy

®

 GS6 and GT6X Series 

Installation Quick Guide

DD3125329
Rev 02
25 June 2020

201 Daktronics Drive

Brookings, SD 57006-5128

www.daktronics.com/support

800.325.8766

Page 1 of 3

Mount Display

For Multi-Section Displays –  See 

Section Splice 

Instructions (p.3)

.

1. 

Lift the display into position on support 

structure. Refer to label at lift eyes for 

information.
•  Maintain a 55-degree or greater angle 

between display and lift straps.

•  Do not adjust or remove lift eyes.
•  Do not lift display in wind speeds greater 

than 20 mph.

2. 

Weld or bolt ALL T-clips to support structure.

Note: 

T-clips can be adjusted within the 

guidelines of the label located at each 

T-clip.

Angle must be 

greater than 55°

L

T-CLIP CAN BE ADJUSTED BUT MUST FALL BETWEEN LINES

Connect Power

Note: 

GT6X displays have multiple power 

entrances depending upon the display 

length.

1. 

Route conduit from the main distribution 

panel/disconnect to each display power 

entrance. In GT6X displays, each display 

section has a power entrance and requires a 

dedicated circuit

2. 

Remove the four screws that attach the power 

entrance access door.

3. 

Connect conduit to the 1 

1

/

4

″ Myers hub at the 

left of the power entrance box.

4. 

Feed power cable from the conduit into the 

power entrance box.

5. 

Connect primary power lines to appropriate 

taps in enclosure – refer to label on enclosure 

for wiring diagram.

6. 

Reinstall power entrance cover.

Отзывы: