Daktronics Galaxy AF-3400 Series Скачать руководство пользователя страница 1

Galaxy

®

 AF-3400  

20 mm Monochrome/RGB 

Double-face Displays 

 

 

Installation and Operation Manual 

 

 

ED-17987 

Rev 0-2 July 2008 

201 Daktronics Dr. PO Box 5128 Brookings SD 57006 
Tel: 866-343-3122 or 605-697-4300 Fax: 605-697-4444 
www.daktronics.com  email: [email protected] 

Содержание Galaxy AF-3400 Series

Страница 1: ...GB Double face Displays Installation and Operation Manual ED 17987 Rev 0 2 July 2008 201 Daktronics Dr PO Box 5128 Brookings SD 57006 Tel 866 343 3122 or 605 697 4300 Fax 605 697 4444 www daktronics c...

Страница 2: ......

Страница 3: ...ion being used Refer to Section 4 for guidance Controller version used in the display Version 3 Display address on network DAKTRONICS INC Copyright 2008 All rights reserved While every precaution has...

Страница 4: ...r Page uses the front of the page blank on back Section heading pages always start on a new page they never start on the back of another page 3 Insert ED 7244 at the end of Section 2 4 Insert the list...

Страница 5: ...the Display 13 Section 4 Signal Installation Overview 15 4 1 RS 422 Communication 16 4 2 Fiber Optic Communication 17 4 3 Radio Communication 18 4 4 RS 232 Communication 19 4 5 Ethernet Communication...

Страница 6: ...arts 39 Module Replacement 39 Controller Replacement 40 Power Supply Replacement 41 Light Sensor 42 Temperature Sensor 43 8 3 Common Power and Signal Connectors 44 8 4 Glossary 45 Section 9 Daktronics...

Страница 7: ...Communication Layout 18 Figure 21 RS 232 Communication Layout 19 Figure 22 Ethernet Communication Layout 20 Figure 23 Fiber Ethernet Communication Layout 21 Figure 24 Ethernet Bridge Radio Layout 22 F...

Страница 8: ...List of Figures iv Figure 48 Phoenix Connector 44 Figure 49 Mate n Lok Connector 44 Figure 50 RJ11 RJ45 45 Figure 51 RS232 6 pin Quick connect Jack 45 Figure 52 Fiber Optic Cable 45...

Страница 9: ...vidual modules can be easily removed from the display if required A typical display system is run with a Windows based personal computer PC running Venus 1500 software Venus 1500 is a software package...

Страница 10: ...gy is illustrated in Figure 2 The diagram in Figure 3 gives an overview of the basic display set up These diagrams will help in the understanding the information in this display manual Figure 2 Displa...

Страница 11: ...ion only and may or may not be appropriate for this particular installation Refer to Figure 3 for basic display set up Refer to Drawing B 310431 for installation details A qualified individual must ma...

Страница 12: ...codes and standards including safe adequate mounting hardware and procedures Note In order to maintain the structural integrity of the display cabinet the 90 angle between the cabinet and the lifting...

Страница 13: ...signal will enter on the left end of Face A and power will enter on the right end 5 Slide the display mounting brackets into the pole mounting brackets on the sign poles and attach them 6 Bring power...

Страница 14: ......

Страница 15: ...display 1 Openings are provided on the display for termination of both signal and power If the installation does not allow for the use of the power J box refer to Section 3 5 for diagrams on internal...

Страница 16: ...AC or 120 240 VAC single phase power source Proper power installation is imperative for proper display operation Power specifications for various display sizes can be found on Drawing A 305814 in Appe...

Страница 17: ...des The material of an earth ground electrode differs from region to region and from conditions present at the site Consult the National Electrical Code and any local electrical codes that may apply S...

Страница 18: ...ation enclosure on the end of the cabinet Option 2 Direct use provided 3 4 conduit opening to go directly to the power termination panel inside the display cabinet Refer to this chart for the method u...

Страница 19: ...ermination panel inside the display 3 Connect the wires coming from the display interior to the power wires using wire nuts Refer to Figure 9 for 120 V termination and Figure 10 for 240 V termination...

Страница 20: ...ht end of the display Use the provided opening for access to the power termination panel being careful not to damage internal components 4 Make the connections as shown in the figures for the appropri...

Страница 21: ...transformer and filter 3 From the termination panel power travels through the transformer which adjusts power to appropriate voltage for use by the controller 4 Power is routed from the power panel to...

Страница 22: ...Power Installation 14 Figure 16 Power Routing Summary...

Страница 23: ...tions equipment Each type is listed below with its manual number Note These are the standard communication types However each site is unique and may include additional equipment If problems arise cont...

Страница 24: ...tions The serial cable connects the computer to the signal converter All the wires are connected at the signal converter and the surge board They need to be making good electrical contact with the met...

Страница 25: ...NOT SHARPLY BEND fiber optic cable at any point along the fiber cable Figure 19 Fiber Serial Communication Layout Troubleshooting Component Check Cable Connections The serial cable is connected from t...

Страница 26: ...Cable Connections The cable connects the computer to the radio j box All the wires are connected at the radio j box and at the server radio the wires make good electrical contact with the metal no int...

Страница 27: ...o display quick connect cable maximum 25 feet from back of enclosure to top jack on side of display Troubleshooting Component Check Cable Connections The serial cable is connected from the laptop to t...

Страница 28: ...from enclosure to middle jack on side of display Troubleshooting Component Check Cable Connections The network cable connects the computer to the network switch router An RJ45 cable from server is con...

Страница 29: ...Troubleshooting Component Check Cable Connections The cable is connected from the computer to the network switch router The network cable connects from network switch to media converter in building T...

Страница 30: ...ght for signal transmission Client radio to display quick connect cable to the middle jack on display side Figure 24 Ethernet Bridge Radio Layout Troubleshooting Component Check Cable Connections A ca...

Страница 31: ...at the modem board Wire color is determined by the phone company The wires are making good electrical contact with the metal no interference The quick connect cable is connected from enclosure to top...

Страница 32: ......

Страница 33: ...a building Refer to Figure 26 for approximate location of the power cable or conduit DIs the control computer connected to the display Some type of communication line or wireless device will send sig...

Страница 34: ...Firmware Number ED 13305 6 Firmware Revision Rev X XX 7 Hardware Address HW XX 8 Software Address SW XX 9 IP Address default IP 172 16 192 25 10 Subnet Msk default Msk 255 255 0 0 11 COM1 Configuratio...

Страница 35: ...The internal components in Daktronics Galaxy AF 3400 series double face displays are accessible by removing the modules from Face A the side with the blue dot and light sensor The display may need to...

Страница 36: ...be reconnected correctly 4 Disconnect the two ribbon cables from the module by spreading the tabs on the sides and then lifting the cable head from the jack Note how they are connected to the back 5...

Страница 37: ...ass button on the thermostat enclosure to temporarily turn on the fans If a fan does not rotate or does not operate smoothly replace it Check the intake and exhaust vents and remove any dust or debris...

Страница 38: ......

Страница 39: ...EDs To access the interior of the display refer to Section 6 1 for instructions Remember to turn off power to the display before accessing the interior However once the modules are removed and wires a...

Страница 40: ...cated inside the temperature sensor housing which mounts near the display Figure 34 The sensor board diagram shows the red diagnostic LED DS2 near the bottom edge of the component Temperature Sensor D...

Страница 41: ...e not lighting Check replace the ribbon cables on the module Check for bent pins on module jacks Move the module to a different location If that does not help the module may need to be replaced One or...

Страница 42: ...ming in Venus 1500 software The Brightness is typically set to Automatic If not perform the following step In Display Manager Diagnostics change the slide bar and click Set Brightness Check the light...

Страница 43: ...this change to the display Note Repeat these steps for each primary display that shows the temperature Temperature always reads 196F 127C degrees Check the temperature sensor cable connections Look f...

Страница 44: ...dress of the display Model number of the display AF 3400 20 mm Double face Version of software being used Right click on Venus 1500 name in toolbar choose About Venus 1500 Method of communication bein...

Страница 45: ...ever on occasion parts may need to be replaced Section 9 provides information on obtaining replacement parts from Daktronics Sections 8 3 and 8 4 include information on the connectors and terms mentio...

Страница 46: ...1R1G1B 1 1 16x16 35x70 RGB 0A 1266 4550 Controller II Louvered Galaxy 8 connector 0A 1229 0013 Power Supply Assembly w Harness A 1577 RGB Displays 0A 1327 0001 1 0A 1327 0002 2 Power Supply Assembly...

Страница 47: ...ing the tabs on the sides of the plug head and pulling out 5 Connect all three cables to the new module making sure that the ribbon cable tabs are tightly pushed against the cable head Carefully push...

Страница 48: ...ote of the address of the controller and set the same address on the replacement controller Controller Address Setting The rotary switches set the hardware address which the software uses to identify...

Страница 49: ...n Figure 42 Note Power supplies in the Schematic drawing are labeled either A or B to designate the Face to which the power supply is connected A Face A B Face B In other words modules on Face A are p...

Страница 50: ...are labeled 2 in the figure 1 Remove the nuts behind the circuit board plate and then remove the plate and circuit board from the assembly 2 Remove the nuts securing the circuit board to the plate 3 R...

Страница 51: ...discs Three of the discs are solid while the center two have a square hole in them to fit around the sensor 2 Label the wires connected to the temperature sensor board and then disconnect the cable f...

Страница 52: ...ocks are commonly used to connect internal power to an external power source Power wires need to have one half inch of insulation stripped from the end of the wire prior to termination Insert wires in...

Страница 53: ...in the jack Push the plug in then turn the outer collar to lock it into place Figure 51 illustrates the 6 pin quick connect jack Fiber Optic Cable A fiber optic network transmits light signal through...

Страница 54: ...ly removable from the front of the display Network Multiple displays connected to each other As many as 240 primary displays can exist on one network Pixel A single LED The number and color of the LED...

Страница 55: ...____________ Daktronics Customer ID Number ______________________________________ To participate in the Exchange Program follow these steps 1 Call Daktronics Customer Service 866 343 3122 2 When the n...

Страница 56: ...tion RMA number before shipping This expedites repair of your component 3 Package and pad the item carefully to prevent damage during shipment Electronic components such as printed circuit boards shou...

Страница 57: ...listed by pixel matrix size Schematic AF 3400 32x80 20 RGB DF Drawing B 305792 Schematic AF 3400 32x96 20 RGB DF Drawing B 305793 Schematic AF 3400 32x112 20 RGB DF Drawing B 305794 Schematic AF 3400...

Страница 58: ......

Страница 59: ...Temperature Sensor Installation 51 Appendix B Temperature Sensor Installation...

Отзывы: