Electrical Installation 

 

12 

4.

 

Mate-n-Lok

 Connectors: 

 

 

The Mate-n-Lok connectors found in the displays are white and come in a 
variety of sizes. 

Figure 11 

on the right

 

illustrates a four-pin Mate-n-Lok 

connector. To remove the plug from the jack, squeeze the plastic locking 
clasps on the side of the plug and pull it from the jack. 

 

5.  Phone Jacks (RJ11 Connectors): 

 

RJ connectors, as seen in 

Figure 12 

on the lower right, are similar to the 

telephone connectors found in homes and are used on the ends of flat RJ11 
cable. In order to remove this plug from the jack, depress the small clip on 
the underside of the plug.

  

 

 

Before replacing an RJ connector, spray it with DeoxIT

 contact cleaner 

to remove any foreign matter that may cause signal problems. In addition, 
apply a generous amount of CaiLube

 protector paste to the plug before 

inserting it into the jack. This paste will protect both the plug and the jack 
from corrosion.  

 

6.

 

Six-Pin Insulation Displacement Connector 

 

The six-pin connectors found in the display are keyed connectors, meaning 
that they will only go together one way and should not be forced. To 
remove the connector squeeze the plastic tab and gently pull the plug from 
the jack. 

3.2

 

Control Cable Requirements 

RS-232 

This cable is a 2-conductor shielded cable used to transmit an RS-232 signal (Daktronics part number 
W-1117). This shielded cable should not be subjected to mechanical flexing after installation. This 
cable is not for direct burial and should be routed in a dedicated, grounded metallic conduit at the base 
of the sign structure. This cable has a maximum length of 25 feet. 

RS-422 

This cable is a 4-conductor shielded cable used to transmit an RS-422 signal (Daktronics part number 
W-1234). This shielded cable consists of paired wires. They should not be subjected to mechanical 
flexing after installation. This cable is not for direct burial and should have one of the following 
routings: 
 

 

In dedicated metallic conduit 

 

Inside buildings 

 if cable is not in conduit, keep away from interference signals.  

 
With interference signals (such as power conductors, intercom, etc.) typically a two-foot separation is 
required. The maximum length of an RS-422 signal cable is 4,000 feet (1.22 km). 

Modem 

The modem option will use standard telephone cable routed through conduit. The local telephone 
company will need to assist in this installation. 
 
Ask the telephone company which colors are used by the TIP, and the RING for signal connections. 

Note:

 The telephone lines must be dedicated lines and 

not

 run through a switch board/communications 

system. 

 

 

Figure 11: 

Mate-

n-Loc Connector 

 

 

Figure 12: 

RJ11 

Connector 

Содержание Galaxy AF-3165

Страница 1: ...Galaxy AF 3165 34mm RGB Type 1 Display Manual ED 13607 Rev 3 21 April 2014 Website www daktronics com Tel 866 343 3122 Fax 605 697 4444 201 Daktronics Dr PO Box 5128 Brookings SD 57006...

Страница 2: ...re Design 7 2 3 Ventilation Requirements 8 2 4 Lifting the Display 8 2 5 Display Mounting 9 2 6 Optional Temperature Sensor Mounting 10 Section 3 Electrical Installation 11 3 1 Common Connectors in th...

Страница 3: ...4 3 Power Summary 32 4 4 Service and Diagnostics 33 Transformer and RFI Filter 34 Controller 35 Modules and Drivers 38 Power Supplies 40 Light Detector 40 Modem 40 Fiber Board 41 RS 422 Surge Suppres...

Страница 4: ...Stripped 14 Figure 16 Ground Conductor 15 Figure 17 Installation with Ground and Neutral Conductor Provided 16 Figure 18 Installation with only Neutral Conductor Provided 17 Figure 19 Signal Terminat...

Страница 5: ...List of Figures iv Figure 37 Fiber Optic Board 41 Figure 38 Surge Suppressor RS422 41 Figure 39 Signal Converters 49...

Страница 6: ...lay is properly grounded with an earth ground electrode at the display 3 Disconnect power when servicing the display 4 Do not modify the display structure or attach any panels or coverings to the disp...

Страница 7: ...ter is needed to convert the computers RS 232 signal to fiber optic signal a minimum of two fibers is required Radio Network The Radio network is a standard communication method that uses radio waves...

Страница 8: ...ted through the displays 1 5 Component Identification The following illustrations depict some of the more commonly accessed Galaxy display components Because Daktronics occasionally alters standard de...

Страница 9: ...erter shown in Figure 2 on the right is a Daktronics supplied unit that converts the data from RS232 to RS422 or RS232 to fiber optic signal The signal converter is connected to the control PC via str...

Страница 10: ...er or signal jack P_ _ denotes a power or signal plug for the opposite jack Finally Daktronics part numbers are commonly found on drawings Those part numbers can be used when requesting replacement pa...

Страница 11: ...y Read both the mechanical and electrical installation sections of this manual before beginning any installation procedures 2 2 Support Structure Design Support structure design depends on the mountin...

Страница 12: ...ic feet per minute must be provided per module 10 6 x 10 6 active area If these requirements are not met the Galaxy display warranty may be void 2 4 Lifting the Display The top of the larger displays...

Страница 13: ...d for mounting purposes Remember to have all mounted displays inspected by a qualified structural engineer It is the customer s responsibility to determine the proper wall mounting method and location...

Страница 14: ...location is a north eave or northern exposure away from direct sun light and above grass This location gives extra stability and accuracy to the sensor because of the added shading usually obtained on...

Страница 15: ...n the sides to unlock and remove the jack Before replacing a ribbon cable connector spray it with DeoxIT contact cleaner to remove any foreign matter that may cause signal problems In addition apply a...

Страница 16: ...le Requirements RS 232 This cable is a 2 conductor shielded cable used to transmit an RS 232 signal Daktronics part number W 1117 This shielded cable should not be subjected to mechanical flexing afte...

Страница 17: ...ctor connector used in the network is an industry standard 6 pin RJ11 This connector can be found on many telephones and LANs The cable used in the network is a standard flat six conductor telephone c...

Страница 18: ...ay size located in Appendix B for approximate locations for power and signal conduit Separate conduit must be used to route Power Signal IN wires Signal OUT wires if signal is required for another dis...

Страница 19: ...quirements for your display size Each uses a 120VAC or 120 240 VAC single phase power source Depending on the module color and display size the power supply may vary Do not connect the displays to any...

Страница 20: ...o reduce the resistance The grounding electrode should be installed within 25 feet of the base of the display The grounding electrode must be connected to the ground terminal in the display panel boar...

Страница 21: ...sure 3 Connect the white neutral wire to neutral bus 4 If one power line is being terminated 120VAC connect the black hot wire to L1 Install jumper per Note 1 on Drawing A 154965 5 If two power lines...

Страница 22: ...ng B 175387 Note The AF 3165 is designed for quicker connection to other displays and to either the temp sensor or a radio Connection of the control equipment to the first display can be done using a...

Страница 23: ...Do not run signal and display power through the same conduit 1 If using a quick connect cable connect from the J box to J33 on the back of the display 2 When connecting directly to the display termin...

Страница 24: ...onnected to the Quick Connect at the display The cable from the signal converter to the display must be routed though conduit Do not run signal and display power through the same conduit Refer to Draw...

Страница 25: ...rter J4 or J5 Wire Color Signal Term Panel TB2 Pin 1 GND Shield Pin 1 SHLD Pin 2 RX P Red Pin 2 D1OUT P Pin 3 RX N Black Pin 3 D1OUT N Pin 4 TX P Green Pin 4 D1IN P Pin 5 TX N White Pin 5 D1IN N Pin 6...

Страница 26: ...ack of the display 2 When connecting directly to the display terminate the phone line to TB5 on the Signal Termination Panel If the phone company provided a phone termination box in the display a stra...

Страница 27: ...J4 J5 An adapter module Daktronics part number 0A 1146 0029 allows the use of a 6 conductor phone cord with RJ11 connectors Daktronics part number 0A 1137 0160 to relay the signal to J3 RS232 IN on th...

Страница 28: ...ctrical Installation 24 Signal Converter to Display Fiber Board Signal Converter Field Cabling Display Fiber Board J2 TX1 Color varies J5 RX2 J3 RX1 Color varies J4 TX2 Figure 28 Fiber Signal Connecti...

Страница 29: ...he cable The cable can be cut and terminated directly to the Signal termination Panel in the display Refer to Drawing A 175387 and the Radio manual ED13348 for the correct cable terminations 1 If usin...

Страница 30: ...Electrical Installation 26 Figure 30 Signal Term Panel...

Страница 31: ...S 422 IN on the second display If the displays are not back to back or are too far apart for the Quick connect interconnect cable to reach a 4 conductor shielded cable of the correct length is used On...

Страница 32: ...he other end terminates at the CAN US DS 8 position terminal block A35 TB4 in the second display Face A CAN DS A35 TB4 Field Cabling Face B CAN US A35 TB4 Pin 6 CAN H Green Pin 2 CAN H Pin 7 CAN L Whi...

Страница 33: ...d to protect the sensor and controller from lightning damage 2 Disconnect the CAN temp sensor cable from the temperature sensor terminal block in the CAN temp sensor housing 0A 1241 4017 3 Cut the cab...

Страница 34: ...housing through conduit to the display 5 Terminate the cable to the 8 position terminal block in the display labeled CAN US DS A35 TB4 Drawing A 175387 shows the terminal block wiring CAN Temp Sensor...

Страница 35: ...the front of the display This section provides the following Galaxy display information Signal Routing Summaries provide a basic explanation of the way signal travels through the display Power Routin...

Страница 36: ...ble from the controller J11 through J16 provide signal out to J2 on the driver of the first column of modules in the display 4 Data exits at J1 and is relayed to J2 of the next driver board and so on...

Страница 37: ...and signal power connectors found on the unit On the Schematics and Component Layout Diagrams the components are denoted as follows Component Denoted As Location Filter and Transformer 0A 1241 4005 I...

Страница 38: ...release the hardware securing it to the inside of the enclosure Position the new transformer in its place and tighten it down Re connect all the wires using the display s schematic as a reference RFI...

Страница 39: ...s which the software uses to identify that particular display When replacing a controller board be sure to set the Rotary switches in the same address configuration as the defective controller Each co...

Страница 40: ...e and Troubleshooting 36 Controller Address Settings S2 Upper S1 Lower Address 0 0 Test Mode 0 1 1 0 2 2 0 3 3 0 4 4 0 5 5 0 6 6 0 7 7 0 8 8 0 9 9 0 A 10 0 B 11 0 C 12 0 D 13 0 E 14 0 F 15 1 0 16 1 1...

Страница 41: ...DS8 Red Speed On when the Ethernet interface is at 100Mbps Off when the Ethernet interface is at 10Mbps DS9 Red Duplex On when the Ethernet interface is at full duplex Off when the Ethernet interface...

Страница 42: ...ers on the module One is centered below the top row of pixels and one is centered above the bottom row 2 With a 1 8 Allen wrench turn the latch access fasteners a quarter turn as seen in Figure 37 on...

Страница 43: ...louver assembly to the module 2 Lift the louver assembly straight away from the module Damaged louvers may reduce the brightness and contrast of this display If any of the louvers on the display are...

Страница 44: ...ination panel The cable is terminated at the terminal block on the light sensor and at the signal termination panel refer to your display s schematic When the displays are mounted back to back only on...

Страница 45: ...s held in place with four screws Carefully remove them 3 Install the new fiberboard replace the screws and reconnect power and signal cables RS 422 Surge Suppressor 1 Disconnect the signal connections...

Страница 46: ...an blades must be kept clean to maintain fan efficiency and ensure proper cooling Spin the fan blades with a pen or pencil to ensure that the bearings are free and the fan is still in balance To check...

Страница 47: ...s the following issues Loose Hardware Verify fasteners such as bolts and rivets have not come loose Fasteners should be checked and tightened or replaced as required Excessive Dust Buildup Occasionall...

Страница 48: ...bled Replace first module Replace ribbon cable to first module Check for bent pins on module and controller Replace controller Check the fuses in the power termination box A group of modules a column...

Страница 49: ...will display the following 1 Product Name Galaxy 2 Display Size Row x Column 3 Shading 32 768 or 8 4 Firmware Number ED13305 5 Operating System OS 3 XX 6 Firmware Revision Rev X XX 7 Hardware Address...

Страница 50: ...1 4013 Filter Air Gasket 7 50 x 13 50 x 88 EN 1774 Fan 250CFM 115VAC 0 65A 5 84x6 0 B 1019 Transformer Pri 115V Sec 10VCT 3A 120V Displays T 1119 Filter RFI Line 10 AMP 120 VAC Z 1007 Fan Finger Guard...

Страница 51: ...ll which represents the exchange price is due when you receive it Daktronics expects immediate return of an exchange part if it does not solve the problem The company also reserves the right to refuse...

Страница 52: ...and Troubleshooting 48 This is how to reach us Mail Customer Service Daktronics Inc PO Box 5128 331 32nd Ave Brookings SD 57006 Phone Daktronics Help Desk 866 343 3122 toll free or 605 697 4034 Fax 6...

Страница 53: ...erial port If connected to serial port Serial port or serial cable may be bad OFF Steady Normal state SC is not transmitting data Brief Flicker SC is transmitting data RX ON Steady Field cabling betwe...

Страница 54: ...pin outs for a fiber signal converter JACK OPERATION J1 25 Pin DB F J2 TX1 out PIN OPERATION J3 RX1 in 2 TX P out J4 TX2 out 3 RX P in J5 RX2 in 7 GND Loop Back Test To perform a loop back for testing...

Страница 55: ...mp Layout Diagram AF 3165 40 48x96 34 RGB Drawing A 172669 Comp Layout Diagram AF 3165 8 32x112 34 RGB Drawing A 172674 Comp Layout Diagram AF 3165 40 48x112 34 RGB Drawing A 172679 Comp Layout Diagra...

Страница 56: ......

Страница 57: ......

Страница 58: ......

Страница 59: ......

Страница 60: ......

Страница 61: ......

Страница 62: ......

Страница 63: ......

Страница 64: ......

Страница 65: ......

Страница 66: ......

Страница 67: ......

Страница 68: ......

Страница 69: ......

Страница 70: ......

Страница 71: ......

Страница 72: ......

Страница 73: ......

Страница 74: ......

Страница 75: ......

Страница 76: ......

Страница 77: ......

Страница 78: ......

Страница 79: ......

Страница 80: ......

Страница 81: ......

Страница 82: ......

Страница 83: ......

Страница 84: ......

Страница 85: ......

Отзывы: