MCL-4000 SERIES 1-

7/8” LED OIL PRESSURE GAUGE 

MCL-4032S/R 

 

 

 

User selectable ranges 0-30 PSI, 0-75 PSI, 0-150 PSI, 0-400 PSI (dependent on sender used) 

 

User adjustable high and low pressure warning points 

 

Fast or slow display update rates  

 

Optional display dimming feature 

 

MOUNTING 

The MCL-4000 series gauge requires a round hole 1-

7/8” diameter.  It should be inserted into the opening from 

the front and the U-clamp will be installed from the back.  Tighten the two nuts on the U-clamp so that the gauge is secure.  
Gauge depth to the back of the case is approximately 1-3/8

”.  Gauge depth including the mounting studs is about 2-1/8”. 

 
PRESSURE GAUGE SETUP 

The green wire in the harness is used to enter setup and change/select settings.  This is done by powering the 

green wire with +12V or releasing it. To power the green wire, touch the wire to a +12V source.  To release the wire, 
remove the green wire from the source. The gauge moves through the setup in the following order:   

 

Software code  >  Sender selection  >  Low pressure warning  >  High pressure warning  >  update speed selection  >  done 

 

  default settings: 

75 PSI sender 

5.0 PSI low warning 

52.0 PSI high warning 

Slow update speed

 

 

 

1.  Make sure the key is off so the gauge is not powered. 
2.  Power the green wire while turning the key on. 
3. 

The display will show “



“, this is the software code. (Newer software versions may have a different code.) 

4.  Release the green wire. The display will 

read “



” (pressure sender selection). 

5.  Power and release the green wire. The currently selected pressure sender type is displayed. 
6.  Power and release the green wire until your pressure sender is displayed. 
7.  Power and hold the green wire to power to store the sender setting.  
8. 



” (low pressure warning) will be displayed. Release the green wire. 

9.  Power and release the green wire to adjust the low pressure warning point. 
10.  Power and hold power to the green wire to store the low pressure warning point. 
11. 



” (high pressure warning) will be displayed. Release green wire. 

12.  Power and release the green wire to adjust the high pressure warning point. 
13.  Power and hold power to the green wire to store the high pressure warning point. 
14. 

“SPd” (update speed) will be displayed. Release green wire. 

15.  Power and release the green wire 

to adjust the update speed between “



” (fast) and “



” (slow). 

16.  Power and hold power to the green wire to save the update speed setting.  Setup is complete. Gauge returns to 

normal operation.  