12V Diaphragm Pump

: For use with non-potable liquids such as water-based

agricultural pesticides and other liquids**

WARNING

READ and UNDERSTAND the Owner’s Manual completely before using this pump

Assemble, test, and use only in accordance with the Owner’s Manual instructions.

READ and FOLLOW chemical safety instructions.

Pesticides are hazardous chemicals.

KNOW emergency procedures BEFORE handling chemicals.

Pump leaks, bodily chemical 

contact, poisoning, and spills require immediate response.

AVOID inhaling, ingesting, or coming into contact with any chemicals.

WEAR personal protective gear when operating, cleaning, and servicing the pump.

KEEP pump and spray materials away from children and pets.

Pesticides are especially 

toxic to them.

DO NOT TURN ON POWER to pump until ready to spray

in order to avoid unintentional 

spray release.

ALWAYS 

keep a fire extinguisher rated “ABC” nearby.

Improper use of the pump or handling of chemicals could result in serious injury or 
illness to the operator or nearby persons/animals, or could cause damage to the 
environment.

**This pump is recommended for use in spraying non-flammable liquids such as pesticides, water 

for plants/trees or dust control, and water-based non-flammable sealants or stains for outdoor wood 
surfaces. The pump will be damaged and warranty voided if used to apply bleach, chlorine, ice 
control chemicals, or any petroleum based product (gasoline, diesel, kerosene, oil). The pump should 
not be used to transfer any product intended for human consumption. WE RECOMMEND THAT 
THE PUMP NOT BE USED FOR OTHER PURPOSES ONCE IT HAS BEEN USED FOR
SPRAYING PESTICIDES. Any chemical will leave some residual in the pump components, even 
after the pump has been properly cleaned. These residual chemicals can have unexpected effects on 
future uses. For example, spraying water or other liquids that are contaminated with residual 
pesticide may result in unforeseen hazards to plant or animal life. This pump should not be used by 
people with reduced physical, sensory or mental capabilities or lack of experience and knowledge.

Any Questions, Comments, Problems, or Parts Orders

Call

 

Daken

 

Product

 

Support

 1800 648 384

ITEM 

NUMBER:

 

D3BP

,

 

D5BP

,

 

D8BP

,

 

D11BP

,

 

D15BP

,

 

D20BP

,

 

D26BP

Содержание M803927

Страница 1: ...injury or illness to the operator or nearby persons animals or could cause damage to the environment This pump is recommended for use in spraying non flammable liquids such as pesticides water for pl...

Страница 2: ...Hazard Signal Word Definitions 2...

Страница 3: ...our Check and test completed assembly 11 Operation Important Safety Information Operation 12 General Chemical Safety Chemical Applicator Safety Chemical Accident Procedures Preparing the Pump for Each...

Страница 4: ...zed form or for use with fumigants In addition to spraying pesticides this pump may be used to spray other non flammable liquids Example uses include watering plants trees or spraying water for dust c...

Страница 5: ...label WEAR protective clothing eye protection and chemical resistant gloves when operating the pump Wear additional protective gear such as facemask or apron as recommended on the chemical label EXER...

Страница 6: ...Personal contamination can occur when chemicals splash spill or spray directly onto a person 1 Immediately follow First Aid instructions on chemical label General procedures can include a Eyes immedia...

Страница 7: ...143001507 D5BP 9349143001514 D8BP 9349143001521 D11BP 9349143001538 D15BP 9349143001545 D20BP 9349143001552 D26BP 9349143001569 Daken 3 8 LPM 1 0 GPM Pump 7 WARNING DO NOT PUMP FLAMMABLE FLUIDS DO NOT...

Страница 8: ...Inside diameter 3 4 19mm Inside diameter D3BP 3 4 Quick Connect 3 8 9 5mm Inside diameter 3 8 9 5mm Inside diameter NOTE Daken does not recommend the use of metal fittings or rigid pipe to plumb the i...

Страница 9: ...with water and neutralize with baking soda 2 Electrical requirements The pump should be on a dedicated individual circuit controlled with a double pole switch UL CSA certified rated at or above the fu...

Страница 10: ...ot in a vehicle WARNING Always connect in this sequence to avoid possible shock D3BP D5BP D8BP D11BP D15BP D20BP Positive red wire Negative black wire D26BP Positive red Negative black 4 Disconnect af...

Страница 11: ...er modify the pump design 1 Check assembly Check assembly to assure the pump is properly assembled and in safe working condition 2 Test with water Test the system for leaks with water a Fill the tank...

Страница 12: ...or coming into contact with the chemical Personal protective equipment ALWAYS wear protective clothing eye protection and chemical resistant gloves when operating and cleaning the pump Wear additional...

Страница 13: ...al manufacturer Excess pesticide can be dangerous to humans damage desirable plants and contaminate soil and water sources Children pets ALWAYS exercise extra caution when spraying near areas accessib...

Страница 14: ...water or follow directions as specified on the chemical label c Clothing remove contaminated clothing immediately Dispose of heavily contaminated clothing per the instructions on the chemical label fo...

Страница 15: ...terials like ground corncobs or pet litter should be spread on the spill area to soak up the pesticide The contaminated material should then shoveled into a leak proof container Do not flush the spill...

Страница 16: ...n a safety hazard or poor operation of the sprayer 1 Ensure clean system Ensure the pump has been thoroughly flushed and drained of all residual chemicals from prior uses 2 Inspect repair Inspect and...

Страница 17: ...ea Clear the work area of all bystanders and pets Restrict access by the public for the period recommended on chemical label Step Two Operate the pump WARNING ALWAYS wear personal protective equipment...

Страница 18: ...er to the pump b Relieve system pressure 6 Discontinue use if clogged or inoperative If the pump becomes clogged or inoperative during use discontinue use immediately DO NOT attempt to service while c...

Страница 19: ...ide is to be stored for future use Store all unused pesticide in its original or a suitably marked container in a secure location out of the reach of children animals b If remaining pesticide is to be...

Страница 20: ...our RV antifreeze into the pump system Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze 2 Spray briefly Turn on the pump and run the...

Страница 21: ...protective equipment as directed on the chemical label while servicing your pump 2 Review troubleshoot ing table Review the Troubleshooting Table below for the type of problem you are experiencing Ho...

Страница 22: ...fittings Replace cracked fittings Worn diaphragm Replace diaphragm assembly Worn valves Replace valve plate assembly Inlet Outlet tube restriction Remove restriction Incorrect voltage Check voltage 10...

Страница 23: ...384 Model Number Electrical connection Maximum amp draw Maximum flow Maximum pressure Ports Overall dimensions Weight D3BP 12 VDC 4 Amps 1 0 GPM 3 8 LPM 40 PSI 2 8 bar 3 4 Quick connect 7 3 x 3 9 x 3...

Страница 24: ...ect fittings are compatible with D3BP D8BP D11BP D15BP D20BP and D26BP Part Description 787212 Quick Connect x 3 8 Hose barb elbow 787213 Quick Connect x 1 2 Hose barb elbow 787215 Quick Connect x 1 2...

Страница 25: ...2 791634 Base plate assembly 1 3 790576 Diaphragm assembly 1 4 790584 Valve plate assembly 1 5 790589 Upper housing assembly 1 6 791635 Pressure switch assembly 1 7 788429 Quick connect clip 2 8 A268...

Страница 26: ...ly 1 2 800428 Base plate assembly 1 3 794988 Diaphragm assembly 1 4 794989 Valve plate assembly 1 5 787015 Quick connect clip 2 6 787011 Upper housing assembly 1 7 786953 Pressure switch assembly 1 8...

Страница 27: ...1 3 788017 Diaphragm assembly D11BP 1 788018 D15BP 788019 D20BP 4 788015 Valve plate assembly All 1 5 787012 Upper housing assembly All 1 6 788689 Pressure switch assembly All 1 7 787015 Quick connec...

Страница 28: ...2 790016 Base plate assembly 1 3 788019 Diaphragm assembly 1 4 788015 Valve plate assembly 1 5 787012 Upper housing assembly 1 6 788689 Pressure switch assembly 1 7 789252 Relay cover 1 8 788929 Rela...

Страница 29: ...6 Motor assembly 1 2 800428 Base plate assembly 1 3 797013 Diaphragm assembly 1 4 798397 Valve plate assembly 1 5 797105 Upper housing assembly 1 6 797407 Pressure switch assembly 1 7 A26815152 Comple...

Страница 30: ...to be replaced or repaired is the sole decision of Daken NOTE Some services performed by parties other than Daken may void warranty This warranty covers parts only It will not provide for replacement...

Страница 31: ...648 384 or email sales clarkfarmequipment com au Operating 8 30am 5pm Monday to Friday Product Technical Support Call us on Toll Free 1800 817 366 or email support clarkfarmequipment com au Operating...