Troubleshooting by Error Code
SiAF332111E
248
Part 6 Service Diagnosis
Note(s)
Reference
5.30 Electronic Expansion Valve Coil Abnormality
Applicable
Models
RXMQ6-12AR
Error Code
E9
Method of Error
Detection
Detect according to whether or not there is continuity across the electronic expansion valve
coils (Y1E, Y2E, Y4E).
Error Decision
Conditions
When no current flows through common (COM+) at the time of turning ON the power supply.
Supposed
Causes
Disconnection of connectors from electronic expansion valves (Y1E, Y2E, Y4E)
Defective electronic expansion valve coil
Defective outdoor unit main PCB
Troubleshooting
1. RXMQ6/8AR: E9-03 (Y2E), E9-26 (Y4E)
RXMQ10/12AR: E9-01 (Y1E), E9-04 (Y2E)
CHECK 18
Refer to page 358.
Turn OFF the power supply
once, and then turn it ON again.
Return to normal?
Investigate external causes other than
failures (e.g. noise).
Replace the outdoor unit main PCB
(A1P).
YES
NO
Connector for
the electronic expansion
valve of the outdoor unit main
PCB (A1P) is
connected.
CHECK 18
The resistance of
the electronic expansion
valve coil is
normal.
Properly and securely connect the
connector.
NO
YES
Is sub code one of
the following?
E9-48, 54
Replace the defective electronic
expansion valve coil.
YES
NO
NO
YES
CHECK 18
The resistance of the
electronic expansion
valve coil is
normal.
Replace the electronic expansion
valve coil.
NO
Replace the outdoor unit main PCB
(A1P).
YES
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Check for electronic
expansion valves applicable
to the error code
E9
while in
monitor mode (
1).
RXMQ6/8AR Only
Содержание VRV S RXMQ10ARY1
Страница 1: ...Service Manual Cooling Only 50 60 Hz RXQ4 5ARV1 RXMQ6ARV1 RXMQ8 10 12ARY1 SiAF332111E...
Страница 349: ...SiAF332111E Check Part 6 Service Diagnosis 343 PCB and Circuit Diagram U V W L3B L2B L1B P1 P2 N32...
Страница 366: ...SiAF332111E 360 Part 7 Appendix 1 Wiring Diagrams 361 1 1 Outdoor Unit 361 1 2 VRV Indoor Unit 366 Part 7 Appendix...
Страница 369: ...SiAF332111E Wiring Diagrams Part 7 Appendix 363 RXMQ6ARV1 C 3D137051...
Страница 370: ...Wiring Diagrams SiAF332111E 364 Part 7 Appendix RXMQ8ARY1 C 3D137060...
Страница 371: ...SiAF332111E Wiring Diagrams Part 7 Appendix 365 RXMQ10 12ARY1 3D121610B...
Страница 375: ...SiAF332111E Wiring Diagrams Part 7 Appendix 369 FXMQ40 50 63 80 100ARV1 3D127112 04 59...
Страница 376: ...Wiring Diagrams SiAF332111E 370 Part 7 Appendix 1 2 4 Wall Mounted FXAQ20 25 32PVE FXAQ40 50 63PVER1 C 3D076498B...