13 Configuration
Installation and operation manual
24
VAM350~2000J8VEB
Heat reclaim ventilation unit
4P664011-1 – 2021.08
Vent
To change the ventilation mode
1
Press the Menu/Enter button to display the main menu.
2
Press the Up/Down buttons to select Ventilation and press the
Menu/Enter button.
Airflow Direction
Individual Air Direction
Quick Start
Ventilation
Energy Saving Options
Schedule
1/2
Setting
Return
Main Menu
3
Press the Up/Down buttons to select Ventilation Mode and
press the Menu/Enter button.
2/2
Ventilation Rate
Ventilation Mode
Ventilation
Setting
Return
4
Press the Up/Down buttons to select the required ventilation
mode. For more information about ventilation modes, see
Ventilation modes in the installer and user reference guide.
Bypass
2/2
Ventilation mode
Ventilation
Setting
Return
Bypass
Energy Reclain Vent.
Auto
Ventilation modes
You can change the ventilation mode in the main menu.
Mode
Description
Auto mode
Using information from the air
conditioner (cooling, heating, fan,
and set temperature) and heat
reclaim ventilation unit (indoor and
outdoor temperatures), this mode
automatically switches between
Heat Reclaim Ventilation mode and
Bypass mode.
Heat Reclaim Ventilation
mode (Energy Reclaim
Ventilation)
Outdoor air is supplied to the room
after passing through a heat
exchange element, where heat is
exchanged with the room air.
Bypass mode
The outdoor air bypasses the heat
exchange element. This means that
outdoor air is supplied to the room
without heat exchange with the room
air.
Time to clean filter indication
When the filter pressure drop becomes too large, the following
message or icon is displayed at the bottom of the basic screen: Time
to clean filter or
. Clean the filters. For more information, see
6].
Cool
Set to
28
°C
Time to clean filter
To remove the Time to clean filter indication
1
Press the Menu/Enter button.
2
Press the Up/Down buttons to select Reset Filter Indicator.
3
Press the Menu/Enter button.
Result:
You return to the basic screen. The Time to clean filter
indication is no longer displayed.
1/3
Setting
Return
Reset Filter Indicator
Airflow Direction
Individual Air Direction
Quick Start
Ventilation
Energy Saving Options
Main Menu
Cool
Set to
28
°C
About error indications
If an error occurs, there is an error icon in the basic screen and the
operation lamp blinks. If a warning occurs, ONLY the error icon
blinks and the operation lamp does NOT. Press the Menu/Enter
button to display the error code or warning and contact information.
Cool
Set to
28
°C
Error : Push Menu Button
The error code blinks and the contact address and model name
appear as shown below. In this case, notify your dealer about the
error code.
Contact Info
0123–4567–8900
Indoor Model
–––/000
Outdoor Model –––/000
Error Code:A1
Return
13.4.2
BRC301B61 controller
NOTICE
This controller is NOT allowed in combination with EKVDX
indoor units.
For non-independent systems, starting, stopping and setting a timer
is NOT possible with this controller (BRC301B61). In such cases,
use the air conditioner controller (BRC1E53) or the central controller.
Содержание VAM-J8 Series
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ...4P664011 1 2021 08 Copyright 2021 Daikin 4P664011 1 0000000G Verantwortung f r Energie und Umwelt...