![Daikin Trailblazer AGZ030E-070E Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/daikin/trailblazer-agz030e-070e/trailblazer-agz030e-070e_installation-operation-and-maintenance-manual_501731045.webp)
Dimensions and Weights - Pump Package Units
www.DaikinApplied.com 45
IOM 1207-6 • TRAILBLAZER
®
MODEL AGZ CHILLERS
Dimensions and Weights - Pump Package Units
Figure 47: Representative Refrigerant System Schematic
A
G
Z
1
4
0
-1
8
0
E
P
A
CKA
G
E
CHI
L
L
E
R
M
ICRO
CHA
NNE
L
A
L
UM
INUM
CO
IL
NO
T
E
:
P
IP
ING
S
HO
W
N
F
O
R
O
NE
S
Y
S
T
E
M
O
F
UNI
T
.
UNI
T
S
H
A
V
E
T
W
O
I
N
D
EPEN
D
EN
T
SY
ST
EM
S.
C
H
A
R
G
IN
G
VA
L
VE
L
IQ
U
ID
T
UBI
NG
L
IQ
U
ID
S
H
U
T
-O
F
F
VAL
VE
F
IL
T
E
R
D
R
IE
R
(R
EPL
AC
EA
BL
E
C
O
R
E)
S
OL
E
N
OI
D
VAL
VE
SI
G
H
T
G
L
AS
S
EL
EC
T
R
IC
AL
EX
PAN
SI
O
N
VA
L
VE
S
U
C
TI
O
N
T
U
B
IN
G
DI
SCHARGE
TU
B
IN
G
AI
R
FL
O
W
AI
R
FL
O
W
C
O
N
D
E
N
S
E
R
A
SS
EM
B
L
Y
S
C
R
O
L
L
C
O
M
PR
ES
SO
R
(T
A
N
D
E
M
O
R
T
R
IO
)
C
HA
RG
ING
V
AL
VE
S
U
C
T
IO
N
T
E
M
P.
S
EN
SO
R
(ST
1
,
ST
2
)
S
U
C
T
IO
N
T
R
A
N
S
D
U
C
E
R
(W
L
1
,
W
L
2
)
D
IS
C
H
A
R
G
E
T
R
A
N
S
D
U
C
E
R
(W
H
1,
W
H
2)
S
C
H
R
AD
ER
V
AL
VE
S
C
H
R
A
D
E
R
VA
L
VE
HOT
GAS
BYPASS
T
UBI
NG
(OPT
IONAL
)
H
G
BP
V
AL
VE
S
OL
E
N
OI
D
V
AL
VE
AC
C
ES
S
FI
TT
IN
G
DI
S
C
HA
RG
E
SH
U
T
-O
F
F
V
AL
VE
W
IT
H
S
C
H
R
A
D
E
R
V
AL
VE
S
C
H
R
A
D
E
R
V
AL
VE
S
C
H
R
A
D
E
R
VA
L
VE
F
U
SI
BL
E
PL
U
G
W
AT
ER
IN
W
AT
ER
OU
T
P
L
A
T
E
T
YP
E
E
V
AP
O
R
A
T
O
R
L
E
AV
IN
G
W
AT
ER
T
EM
P.
SE
N
S
O
R
F
L
O
W
S
EN
SO
R
(O
P
T
IO
N
A
L
)
W
Y
E
S
T
R
A
IN
E
R
R
E
Q
U
IR
E
D
(F
A
C
T
O
R
Y
O
R
F
IE
L
D
IN
ST
AL
L
ED
)
O
IL
S
IG
H
T
G
L
AS
S
O
IL
H
E
AT
ER
O
U
T
S
ID
E
A
IR
T
E
M
P
ER
AT
U
R
E
(W
A
A
)
L
O
C
A
T
E
D
O
N
C
O
N
D
E
N
S
E
R
R
A
IL
H
OT
GA
S
S
H
U
T-
O
FF
VAL
VE
A
IR
FL
O
W
S
C
H
R
A
D
E
R
VA
L
VE
A
IR
FL
O
W
D
IS
C
HA
RG
E
H
IG
H
PR
ESS
U
R
E
S
W
ITC
H
S
U
C
T
IO
N
S
H
UT
-O
F
F
BA
L
L
VA
L
VE
W
IT
H
S
C
H
R
A
D
E
R
V
A
L
V
E
(OP
T
ION
)
L
IQ
U
ID
L
IN
E
C
H
EC
K
VAL
VE
D
ISC
H
A
R
G
E
SO
L
EN
O
ID
VA
L
VE
AI
R
FL
O
W
EN
T
ER
IN
G
W
AT
ER
T
EM
P
ER
AT
U
R
E
SEN
SO
R
334
54
9802
0
D
Refrigerant schematic
is representative of typical packaged
AGZE
unit
with microchannel coils. Number of fans may be
different than shown.
Содержание Trailblazer AGZ030E-070E
Страница 4: ......
Страница 145: ... www DaikinApplied com 145 IOM 1207 6 TRAILBLAZER MODEL AGZ CHILLERS ...
Страница 146: ...IOM 1207 6 TRAILBLAZER MODEL AGZ CHILLERS 146 www DaikinApplied com ...