manualshive.com logo in svg
background image

• Outdoor Units • R-410A • RZQ71-140C7V1B

1

1

• Split Sky Air • Outdoor Units

1

1

Features

O

u

t

d

o

o

r

 

U

n

i

S

p

l

i

t

 

S

k

y

 

A

R

Z

Q

7

1

-

1

4

0

C

7

V

1

R

-

4

1

0

A

Outdoor units for pair, twin, triple, double twin application

The Sky Air Inverter is developed for use in shops, restaurants and 
small offices.  This innovative Daikin unit provides a more 
comfortable environment and offers great savings in energy 
consumption to shop and office owners.

The use of inverter type outdoor units results in an air conditioning 
system with a high energy efficiency and very low sound level

An inverter driven compressor allows the capacity to be adjusted 
precisely to match variations in room and outside temperatures.

During start up, the room can be cooled down or heated very quickly.  
Once the temperature in the room has reached its set point, the low 
power operation starts to save energy.

Daikin outdoor units are neat and sturdy and can be mounted easily 
on a roof or terrace or simply placed against an outside wall.

Outdoor units are fitted with either a swing or scroll compressor, 
renowned for low noise and high energy efficiency

A special acryl precoated fin for anti-corrosion treatment on the heat 
exchanger ensures greater resistance against severe weather 
conditions

Содержание RZQ71C7V1B

Страница 1: ...rgy efficiency and very low sound level An inverter driven compressor allows the capacity to be adjusted precisely to match variations in room and outside temperatures During start up the room can be...

Страница 2: ...P Nominal 3 62 3 71 3 54 3 21 Energy Label Cooling A A A D Heating A A B C Annual energy consumption kWh 1 055 1385 1940 2680 Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ140B8V3B Cooling capaci...

Страница 3: ...terial Paintable galvanized steel plate Dimensions Unit Height mm 770 1170 1170 1170 Width mm 900 900 900 900 Depth mm 320 320 320 320 Packing Height mm 900 1349 1349 1349 Width mm 980 980 980 980 Dep...

Страница 4: ...l Expansion valve electronic type Nr of Circuits 1 1 1 1 Refrigerant Oil Type FVC50K Daphne FVC68D Daphne FVC68D Daphne FVC68D Charged Volume l 0 75 1 0 1 0 1 0 Piping connections Liquid OD Quantity 1...

Страница 5: ...Power Supply Name V1 Phase 1 1 1 1 Frequency Hz 50 50 50 50 Voltage V 220 240 Voltage range Minimum V 198 198 198 198 Maximum V 264 264 264 264 Current Recomended fuses A 20 32 32 32 Wiring connection...

Страница 6: ...B 2 TOCA means the total value of each OC set 3 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range lim...

Страница 7: ...ns the total value of each OC set 3 Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4 Maximu...

Страница 8: ...RZQ71 140C7V1B 4 Options RZQ100 125 140C Name of option Kit name RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Central drain plug KKPJ5F180 Refrigerant branch piping Twin KHRQ22M20TA Triple KHRQ127H Double twi...

Страница 9: ...edium ESP 4way ceiling Ceiling suspended Outdoor unit Wall mounted Refrigerant R410A Possible indoor combination Simultaneous operation Outdoor models Twin Triple Double twin RZQ100C7V1B 50 50 KHRQ22M...

Страница 10: ...4way ceiling EDP room specifications Ceiling suspended Outdoor unit Wall mounted Refrigerant R410A 3TW29189 2 NOTES 1 Individual indoor capacities are not given because the combinations are for simult...

Страница 11: ...2 On the figure the mark j show the max at standard conditions On the figure the mark Q show rated capacity and rated coefficient of power input However the max capacity is not guaranteed except at s...

Страница 12: ...rated capacity is 7 C DB 6 C WB heating Corresponding refrigerant piping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The va...

Страница 13: ...ping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The value contains less than 5 error acording to indoor unit type 7 Heatin...

Страница 14: ...DB 6 C WB heating Corresponding refrigerant piping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The value contains less than...

Страница 15: ...nly valid for pair combination with FBQ140 2 Ratings shown are net capacities which include a deduction for indoor fan motor heat 3 On the figure the mark j show the max at standard conditions On the...

Страница 16: ...door Units 16 Outdoor Units R 410A RZQ71 140C7V1B 5 Capacity tables 5 2 Cooling capacity tables 3TW26062 1 RZQ B C Capacity Field piping length m Cooling Heating Capacity in function of field piping l...

Страница 17: ...ties which include a deduction for indoor fan motor heat 2 On the figure the mark j show the max at standard conditions On the figure the mark Q show rated capacity and rated coefficient of power inpu...

Страница 18: ...7 C DB 6 C WB heating Corresponding refrigerant piping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The value contains less...

Страница 19: ...t of power input is the percentage when the rated value is defined as 1 00 6 The value contains less than 5 error acording to indoor unit type 7 Heating performance include the drop of frost formation...

Страница 20: ...erant piping length 5 0m Level difference 0m 5 Coefficient of power input is the percentage when the rated value is defined as 1 00 6 The value contains less than 5 error acording to indoor unit type...

Страница 21: ...oefficient of power input NOTES 1 This capacity table is only valid for pair combination with FBQ140 2 Ratings shown are net capacities which include a deduction for indoor fan motor heat 3 On the fig...

Страница 22: ...5 Refrigerant piping intake 6 Power supply wiring intake knock out hole J34 7 Control wiring intake Knock out hole J27 8 Drain outlet RZQ C Hole for anchor bolt 4 M12 3TW26364 1 1 Gas pipe connection...

Страница 23: ...Outdoor Units R 410A RZQ71 140C7V1B 1 6 Split Sky Air Outdoor Units 23 6 Dimensional drawing centre of gravity 6 2 Centre of gravity 4TW30469 3 RZQ71C7V1B 4TW29169 4 RZQ100 125 140C...

Страница 24: ...ressure switch Filter Low pressure sensor 3TW29165 2 RZQ71 140C Twin Indoor unit Field piping J15 9 Field piping J9 5 Low pressure sensor Heat exchanger Filter Stop valve with service port 5 16 flare...

Страница 25: ...ranch and the indoor units should have the same size as the indoor connections 3TW29165 4 RZQ100 125 140C Double twin Indoor unit Field piping J15 9 Field piping J9 5 Low pressure sensor Heat exchange...

Страница 26: ...rcuit board Main A2P Printed circuit board Inverter BS1 BS4 Push button switch C1 C3 Capacitor DS1 Dip switch F1U Fuse T 6 3A 250V F6U Fuse T 3 15A 250V H1P 7P A2P Light emitting diode service monitor...

Страница 27: ...ssure level A scale according to IEC 3 Reference acoustic pressure 0dB 20 Pa 4 Data is valid at nominal operation condition Measuring location discharge side 3TW29167 1 Sound pressure level dB Octave...

Страница 28: ...peration condition 3 dB A A weighted sound pressure level A scale according to IEC 4 Reference acoustic pressure 0dB 20 Pa Measuring location discharge side 3TW29207 1 Sound pressure level dB Octave b...

Страница 29: ...0CV1 NOTES 1 dB A A weighted sound pressure level A scale according to IEC 2 Reference acoustic intensity 0dB 10E 6 W m2 3 Measured according to ISO 3744 3TW29197 3 Sound power level dB Octave band ce...

Страница 30: ...per row RZQ71 140C A Non stacked installation 2 Obstacles exist in front of the air inlet B Stacked installation Legend C Multiple row installation Relation of dimensions of H A and L are shown in the...

Страница 31: ...g To reduce the freeze up operation indoor de icing frequency it is recommended to install the outdoor unit in a location not exposed to wind 3TW29163 2 RZQ71 140C7V1B EDP ROOM Outdoor temp CDB Operat...

Отзывы: