Procedure to Remove Outside Panels
Si341211
2
Removal Procedure
1. Procedure to Remove Outside Panels
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1
2
3
4
5
Remove 8 screws of
the top panel.
Remove 1 screw of the
front panel (2), and then
remove the panel after
pushing it downward to
release the hook.
To remove the front
panel for piping cover,
remove its 1 screw.
To remove the side
panel for piping cover,
remove 4 screws of the
side panel.
To remove the side
panel, remove its 6
screws after removing
the outdoor air
thermistor.
It is possible to remove only
the front panel without
removing the top panel.
Hook
Top panel
Front panel
(2)
Front panel for
piping cover
Side panel
Side panel for
piping cover
Outdoor air
thermistor