SiUS092230EA
ARC466A36
Part 5 Remote Controller
97
Reference
2. ARC466A36
Refer to the following pages for details.
Signal transmitter
Powerful
1
button
• Starts POWERFUL operation.
Display (LCD)
• Changes the temperature setting.
On/Off button
Auto
Indoor unit quiet
Low
Middle low
Middle
Middle high
High
• Press this button once to start
operation.
Press once again to stop it.
Temperature adjustment
buttons
• Displays the current settings.
(In this illustration, each section is
shown with all its displays on for the
purpose of explanation.)
• To use the remote controller, aim the
transmitter at the indoor unit. If there
is anything to block signals between
the unit and the remote controller,
such as a curtain, the unit will not
operate.
• The maximum distance for
communication is about 19-11/16 ft
(6 m).
Make sure that there are no
obstacles within 19-11/16 inch (50
cm) under the signal receiver.
Such obstacles, if any, may have an
adverse influence on the reception
performance of the receiver and the
reception distance may be
shortened.
Fan setting button
• In indoor unit quiet operation,
operation sound becomes weak.
(The airflow rate also decreases.)
• In DRY operation, the airflow rate
setting is not available.
• Selects the airflow rate setting.
(R24594)
Receiver
19-11/16"
(50 cm)
or more
: AUTO
: DRY
: COOL
: HEAT
: FAN
18 ~ 30
°
C
(64 ~ 86
°
F)
Not available
18 ~ 32
°
C
(64 ~ 90
°
F)
10 ~ 30
°
C
(50 ~ 86
°
F)
Not available
< ARC466A36 >
1 POWERFUL Operation
P.50
Содержание RX-W Series
Страница 1: ... Applied Models Inverter Pair Heat Pump Service Manual SiUS092230EA Inverter Pair RX W Series ...
Страница 15: ...SiUS092230EA Part 1 General Information 9 1 Applicable Models 10 2 Functions 11 Part 1 General Information ...
Страница 107: ...SiUS092230EA BRC082A41W BRC082A42W S Part 5 Remote Controller 101 4 BRC082A41W BRC082A42W S R23936 R23937 ...
Страница 151: ...SiUS092230EA Troubleshooting for FDMQ FFQ Series Part 6 Service Diagnosis 145 Reference Check No 02 Refer to P 191 ...
Страница 207: ...SiUS092230EA Check Part 6 Service Diagnosis 201 15 18 24 class R25105 1 2 3 4 Multimeter ...
Страница 209: ...SiUS092230EA Check Part 6 Service Diagnosis 203 15 18 24 class R20704 W V U DC_P1 DC_N1 ...
Страница 238: ...Piping Diagrams SiUS092230EA 232 Part 8 Appendix 1 2 Outdoor Unit RX09 12WMVJU9 RX15 18WMVJU9 3D135014 3D141501 ...
Страница 239: ...SiUS092230EA Piping Diagrams Part 8 Appendix 233 RX24WMVJU9 3D141502 ...
Страница 246: ...Operation Limit SiUS092230EA 240 Part 8 Appendix 3 Operation Limit RX09 12 15 18 24WMVJU9 3D092209F ...