SiUS181305E
Test Operation
Test Operation and Field Settings
94
1.5
SA Indoor Unit: FFQ Series
1.5.1 Checkpoints
To carry out a test operation, check the following:
Check that the temperature setting of the remote controller is at the lowest level in cooling
operation or use test operation mode.
Go through the following checklist:
1.5.2 Test operation
BRC1E72
Checkpoints
Cautions or warnings
Are all units securely installed?
Dangerous for turning over during storm
Possible damage to pipe connections
Is the ground wire installed according to the applicable
local standard?
Dangerous if electric leakage occurs.
Are all air inlets and outlets of the indoor and outdoor units
unobstructed?
Poor cooling
Poor heating
Does the drain flow out smoothly?
Water leakage
Is piping adequately heat-insulated?
Water leakage
Have the connections been checked for refrigerant
leakage?
Poor cooling
Poor heating
Stop
Is the power supply voltage conform to the specifications
on the name plate?
Incorrect operation
Are the cable sizes as specified and according to local
regulations?
Damage of cables
Are the remote controller signals received by the unit?
No operation
Step
Action
Remote controller
Before test operation
1
Turn on the power supply more than 6 hours
before test operation.
2
Open the gas stop valve.
3
Open the liquid stop valve.
How to activate test operation
4
Press and hold the
Cancel
button for 4
seconds to enter the
Service Settings
menu.
5
Use the
buttons to select
Test Operation
and push the
Menu/OK
button.
6
Test Operation
is displayed on the bottom of
the basic screen.
7
Push the
On/Off
button within 10 seconds to
start the test operation.
(R18827)
(R18828)
Содержание RMXS-L Series
Страница 10: ...Safety Considerations Safety Considerations ix...
Страница 11: ...SiUS181305E 1 List of Functions Part 1 List of Functions 1 Functions 2 1 1 Outdoor Unit 2 1 2 Indoor Unit 3...
Страница 129: ...SiUS181305E Field Settings Test Operation and Field Settings 120...
Страница 144: ...FFQ09 12 15 18LVJU SiUS181305E 135 Remote Controller...
Страница 249: ...SiUS181305E Removal Procedure Booklet No Appendix 240...