Removal of Four Way Valve
Si001073
24
Removal Procedure
7. Removal of Four Way Valve
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the peripheries.
1
Remove the terminal
cover.
2
Remove the screw and
remove the four way
valve coil.
3
Disconnect the
terminals of the
compressor.
4
Remove the overload
protector.
(R15005)
Terminal cover
(R12653)
There are 2 hooks at the inner
side of the terminal cover.
(R11799)
Four way valve coil
(R14529)
U (red)
V (yellow)
W (blue)
Overload
protector