IM 893-10 • ROOFPAK SINGLEZONE UNITS 144 www.DaikinApplied.com
r
ePlaCeMenT
P
arTs
l
IsT
r
ePlaCeMenT
P
arTs
l
IsT
Component Designation
Description
Daikin Part Number
MCB
Main Controller—must be programmed (unit GO# required)
193407301
NA
Connector, Extension I/O Direct Connect
193409701
NA
Terminal Block, MCB–2 Pole
193410302
NA
Terminal Block, MCB–3 Pole
193410303
NA
Terminal Block, MCB–5 Pole
193410305
NA
Terminal Block, MCB–6 Pole
193410306
NA
Terminal Block, MCB–7 Pole
193410307
NA
Terminal Block, MCB–8 Pole
193410308
EXP A
Expansion Module—Condenser/Energy Recovery
193407501
EXP B
Expansion Module—Heat
193407501
EXP C
Expansion Module—Specials
193407501
NA
Terminal Block, MCB–2 Pole
193410302
NA
Terminal Block, MCB–3 Pole
193410303
NA
Terminal Block, MCB–7 Pole
193410307
NA
Terminal Block, MCB–8 Pole
193410308
CCB1
Auxiliary Cooling Control Board (DX Circuit #1 or generic condenser)
112026101 (replaces 106102701)
CCB2
Auxiliary Cooling Control Board (DX Circuit #2)
112026101 (replaces 106102701)
EHB1
Auxiliary Electric Heat Control Board
112026101 (replaces 106102701)
ERB1
Auxiliary Energy Recovery Control Board
112026101 (replaces 106102801)
—
RS-485 Communication Module (for Auxiliary Control Boards)
060006202
—
Standoffs for mounting RS-485 Communication Module (PN 060006206) onto Auxiliary Control Board (PN 112026101)
048166707
—
Keypad/Display
060006301
—
Keypad-Main Control Board Cable
111044601
ZNT1
Zone Temperature Sensor with Tenant Override
111048101
Zone Temperature Sensor with Tenant Override & Remote Setpoint Adjustment (SCC units only)
111048102
DAT
Discharge Air Temperature Sensor (50 ft cable length-field cut to length)
060004705
EFT
Entering Fan Air Temperature Sensor (50 ft cable length-field cut to length)
060004705
OAT
Outside Air Temperature Sensor (50 ft cable length-field cut to length)
060004705
RAT
Return Air Temperature Sensor (50 ft cable length-field cut to length)
060004705
SPS1
Static Pressure Sensor: Duct, No. 1
049545007
SPS2
Static Pressure Sensor: Duct, No. 2
049545007
Static Pressure Sensor: Building (Space) Pressure
049545006
T2
Transformer: 115/24 V (ac)
060004601
T3
Transformer: 115/24 V (ac)
060004601
T9
Transformer: 115/24 V (ac)
060630801
HUM1
Humidity Sensor: Wall Mount
067294901
Humidity Sensor: Duct Mount
067295001
PC5
Dirty Filter Switch: First Filter Section
065493801
PC6
Dirty Filter Switch: Final Filter Section
065493801
PC7
Airflow Proving Switch
060015801
DHL
Duct High Limit Switch
065493801
OAE
Enthalpy Control: Electromechanical
030706702
Enthalpy Control: Electronic (Used with RAE)
049262201
RAE
Return Air Enthalpy Sensor (Used with Electronic OAE)
049262202
SD1
Smoke Detector: Supply Air
049025001
SD2
Smoke Detector: Return Air
049025001
—
BACnet MS/TP Communication Module (RS485)
090016710
—
BACnet/IP Communication Module (Ethernet Cable 10BASET)
090016709
—
LonMark Space Comfort Controller (SCC) Communication Module
090016712
—
LonMark Discharge Air Controller (DAC) Communication Module
090016711
—
5 V (dc) Power Supply
111049601
—
Serial Port Ribbon
111047201
—
MCB Battery
BR2325
—
MCB Connector Repair Kit
300036605
—
Power Disconnect Switch
033696300
—
18 in. Lamp Holder
205484001
—
24 in. Lamp Holder
205484101
—
36 in. Lamp Holder
205484201
—
Hard Wire Module
205485501
—
18 in. Lamp
205484501
—
24 in. Lamp
205484601
—
36 in. Lamp
205484701
Содержание RDT
Страница 60: ...IM 893 10 ROOFPAK SINGLEZONE UNITS 60 www DaikinApplied com Wiring Diagrams Figure 64 VFD Control SAF and RAF...
Страница 61: ...Wiring Diagrams www DaikinApplied com 61 IM 893 10 ROOFPAK SINGLEZONE UNITS Figure 65 VAV Control Inputs...
Страница 65: ...Wiring Diagrams www DaikinApplied com 65 IM 893 10 ROOFPAK SINGLEZONE UNITS Figure 67 Electric Heat Control...